List of Functions
SiENBE04-512A
2
List of Functions
1. List of Functions
1.1
High Grade Models
Category
Functions
ATKS20-35D
VMB
ARKS
2
0
-35CVMB(9)
ATXS20-35D
VMB
ARXS
2
0
-35CVMB(9)
Category
Functions
ATKS20-35D
VMB
ARKS
2
0
-35CVMB(9)
ATXS20-35D
VMB
ARXS
2
0
-35CVMB(9)
Basic
Function
Inverter (with Inverter Power Control)
{
{
Health &
Clean
Air Purifying Filter with Bacteriostatic,
Virustatic Functions
—
—
Operation Limit for Cooling (°CDB)
H
1
–10
~46
–10
~46
Operation Limit for Heating (°CWB)
—
–15
~20
Photocatalytic Deodorizing Filter
—
—
PAM Control
{
{
Air Purifying Filter with Photocatalytic
Deodorizing Function
{
{
Compressor
Oval Scroll Compressor
—
—
Titanium Apatite Photocatalytic
Air-Purifying Filter
—
—
Swing Compressor
{
{
Rotary Compressor
—
—
Mold Proof Air Filter
{
{
Reluctance DC Motor
{
{
Wipe-clean Flat Panel
{
{
Comfortable
Airflow
Power-Airflow Flap
—
—
Washable Grille
—
—
Power-Airflow Dual Flaps
{
{
Mold Proof Operation
—
—
Heating Dry Operation
—
—
Power-Airflow Diffuser
—
—
Good-Sleep Cooling Operation
—
—
Wide-Angle Louvers
{
{
Timer
24-Hour On/Off Timer
{
{
Vertical Auto-Swing (Up and Down)
{
{
Night Set Mode
{
{
Horizontal Auto-Swing (Right and Left)
—
—
Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure)
{
{
3-D Airflow
—
—
Self-Diagnosis (Digital, LED) Display
{
H
2
{
H
2
Comfort Airflow Mode
—
—
Wiring Error Check
—
—
3-Step Airflow (H/P Only)
—
—
Anticorrosion Treatment of Outdoor
Heat Exchanger
{
{
Comfort
Control
Auto Fan Speed
{
{
Indoor Unit Silent Operation
{
{
Flexibility
Multi-Split / Split Type Compatible
Indoor Unit
{
{
Night Quiet Mode (Automatic)
—
—
Outdoor Unit Silent Operation (Manual)
{
{
Flexible Voltage Correspondence
{
{
Intelligent Eye
{
{
High Ceiling Application
—
—
Quick Warming Function
—
{
Chargeless
10m
10m
Hot-Start Function
—
{
Either Side Drain (Right or Left)
{
{
Automatic Defrosting
—
{
Power Selection
—
—
Operation
Automatic Operation
—
{
Remote
Control
5-Rooms Centralized Controller
(Option)
{
{
Programme Dry Function
{
{
Remote Control Adapter
(Normal Open-Pulse Contact) (Option)
{
{
Fan Only
{
{
Lifestyle
Convenience
New Powerful Operation (Non-Inverter)
—
—
Remote Control Adapter
(Normal Open Contact) (Option)
{
{
Inverter Powerful Operation
{
{
Priority-Room Setting
—
—
DIII-NET Compatible (Adapter) (Option)
{
{
Cooling / Heating Mode Lock
—
—
Remote
Control
Infrared
{
{
Home Leave Operation
{
{
Wired
—
—
ECONO Mode
—
—
Indoor Unit On/Off Switch
{
{
Signal Reception Indicator
{
{
Temperature Display
—
—
Another Room Operation
—
—
Note:
{
: Holding Functions
— : No Functions
H
1 :
H
2 :
Lower limit can be extended to –15°C by cutting
jumper. (facility use only)
Digital Only
SiENBE04-512A.book Page 2 Friday, October 5, 2007 1:49 PM
Содержание FTKS20CVMB(9)
Страница 1: ...SiENBE04 512A Service Manual Inverter Pair Wall Mounted Type C Series D Series...
Страница 17: ...List of Functions SiENBE04 512A 8 List of Functions...
Страница 18: ...SiENBE04 512A Specifications 9 Part 2 Specifications 1 Specifications 10 1 1 Cooling Only 10 1 2 Heat Pump 16...
Страница 37: ...Specifications SiENBE04 512A 28 Specifications...
Страница 73: ...Control Specification SiENBE04 512A 64 Function and Control...
Страница 103: ...Instruction SiENBE04 512A 94 System Configuration...
Страница 147: ...Check SiENBE04 512A 138 Service Diagnosis...
Страница 225: ...Outdoor Unit RK X H C ARK X H C R Y N C SiENBE04 512A 216 Removal Procedure...
Страница 226: ...SiENBE04 512A Others 217 Part 8 Others 1 Others 218 1 1 Test Run from the Remote Control 218 1 2 Jumper Settings 219...
Страница 229: ...Others SiENBE04 512A 220 Others...
Страница 241: ...Wiring Diagrams SiENBE04 512A 232 Appendix...
Страница 245: ...SiENBE04 512A iv Index wiring diagrams 229...