EHBH/X16
Daikin Altherma - Low Temperature Split
4P313776-1 – 2012.05
Installer reference guide
6
4 About the units and options
Remote sensor for wireless thermostat (EKRTETS)
You can use a wireless indoor temperature sensor (EKRTETS) only
in combination with the wireless thermostat (EKRTR1).
For installation intructions, see the installation manual of the room
thermostat and addendum book for optional equipment.
Digital I/O PCB (EKRP1HB)
The digital I/O PCB is required to provide following signals:
Q
Alarm output
Q
Space heating/cooling On/OFF output
Q
Changeover to external heat source
Q
Only for EHBH/X16 models: Can be integral part of solar kit
EKSOLHW
For installation instructions, see the installation manual of the digital
I/O PCB and addendum book for optional equipment.
Demand PCB (EKRP1AHTA)
To enable the power saving consumption control by digital inputs you
must install the demand PCB.
For installation instructions, see the installation manual of the
demand PCB and addendum book for optional equipment.
Remote indoor sensor (KRCS01-1)
By default the internal user interface sensor will be used as room
temperature sensor.
As an option the remote indoor sensor can be installed to measure
the room temperature on another location.
For installation instructions, see the installation manual of the remote
indoor sensor and addendum book for optional equipment.
Remote outdoor sensor (EKRSCA1)
By default the sensor inside the outdoor unit will be used to measure
the outdoor temperature.
As an option the remote outdoor sensor can be installed to measure
the outdoor temperature on another location (e.g. to avoid direct
sunlight) to have an improved system behaviour.
For installation instructions, see the installation manual of the remote
outdoor sensor.
PC configurator (EKPCCAB1)
The PC cable makes a connection between the switch box of the
indoor unit and a PC. It gives the possibility to upload different
language files to the user interface and indoor parameters to the
indoor unit. For the available language files, contact your local dealer.
The software and corresponding operating instructions are available
on Daikin Extranet.
For installation instructions, see the installation manual of the PC
cable.
Drain pan kit (EKHBDPCA2)
The drain pan is required to drain accumulated condensation from
the indoor unit. It is required during low temperature cooling
operation of the indoor unit and when the leaving water temperature
is <18°C.
For installation of this option into the indoor unit, refer to the
installation manual delivered with this option kit.
Solar kit (EKSOLHW)
The solar kit is required to connect the solar application with the
domestic hot water tank.
For installation, see the installation manual of the solar kit and
addendum book for optional equipment.
Domestic hot water tank
The domestic hot water tank can be connected to the indoor unit for
providing domestic hot water.
The domestic hot water tank is available in 2 types:
Q
Stainless steel tank (EKHWS and EKHWSU (only for UK))
There are 3 types available: 150, 200, and 300 liter.
Q
Enamelled tank (EKHWE and EKHWET (wallmounted version))
There are 3 types of EKHWE: 150, 200, and 300 liter.
There is 1 type of EKHWET: 150 liter.
For installation instructions, see the installation manual of the
domestic hot water tank and addendum book for optional equipment.
4.2.2 Possible combinations of indoor unit and outdoor unit
INFORMATION
Q
The remote indoor sensor can only be used in case
the user interface is configured with room thermostat
functionality.
Q
You can only connect either the remote indoor sensor
or the remote outdoor sensor.
INFORMATION
You can only connect either the remote indoor sensor or
the remote outdoor sensor.
Outdoor unit
Indoor unit
EHBH16CA3V
EHBX16CA3V
EHBH16CA9W
EHBX16CA9W
ERHQ011BAV3
O
O
O
O
ERHQ014BAV3
O
O
O
O
ERHQ016BAV3
O
O
O
O
ERLQ011CAV3
O
O
O
O
ERLQ014CAV3
O
O
O
O
ERLQ016CAV3
O
O
O
O
ERHQ011BAW1
O
O
O
O
ERHQ014BAW1
O
O
O
O
ERHQ016BAW1
O
O
O
O
ERLQ011CAW1
O
O
O
O
ERLQ014CAW1
O
O
O
O
ERLQ016CAW1
O
O
O
O
Содержание ERLQ011CA
Страница 83: ......
Страница 84: ...4P313776 1 2012 05 Copyright 2012 Daikin ...