Installer reference guide
29
EHBH/X16
Daikin Altherma - Low Temperature Split
4P313776-1 – 2012.05
7 Installation
From the top
From the top center
4
Reinstall the faceplate onto the wallplate.
7.4.6 To connect the shut-off valve
1
Connect the valve control cable to the appropriate terminals as
shown in the illustration below.
2
Fix the cable with cable ties to the cable tie mountings.
7.4.7 To connect the electrical meters
1
Connect the electrical meters cable to the appropriate terminals
as shown in the illustration below.
2
Fix the cable with cable ties to the cable tie mountings.
7.4.8 To connect the domestic hot water pump
1
Connect the domestic hot water pump cable to the appropriate
terminals as shown in the illustration below.
2
Fix the cable with cable ties to the cable tie mountings.
7.4.9 To connect the alarm output
1
Connect the alarm output cable to the appropriate terminals as
shown in the illustration below.
2
Fix the cable with cable ties to the cable tie mountings.
a
Notch this part for the wiring to pass through with nippers
etc.
b
Secure the wiring to the front part of the casing using the
wiring retainer and clamp.
NOTICE
Wiring is different for a NC (normal closed) valve and a NO
(normal open) valve.
a
b
PCB
b
1x
a
PCB
b
b
1x
X1M
X2M
5
6
7
M2S
X1M
X2M
5
6 7
M2S
NO
NC
a
Installation of EKRP1HB is required.
X2M
X5M
7 8 910
S2S S3S
X2M
35
34
1~
M
M2P
X1M
X2M
29
X1M
YC
Y1
Y2
Y3
Y4
A4P
X2M
a