background image

Operation manual

5

EKHVWQ0 E260AA1V3

Domestic hot water heat pump

4PW65343-1A – 10.2010

Name and function of buttons and icons

1.

HEATING DOMESTIC WATER ON/OFF BUTTON 

Y

The ON/OFF button starts or stops the normal heating function
of the unit.

Pressing the ON/OFF button consecutively too many times may
cause malfunction of the system (maximum 20 times per hour).

2.

OPERATION LED 

0

The operation LED is lit when domestic water heating is
possible. The LED blinks if a malfunction occurs. When the LED
is OFF, normal heating is not possible while the safety modes
can still be active.

3.

OPERATION MODE ICONS 

ws

These icons indicate the current operation mode(s): domestic
water heating (

w

) or quiet mode (

s

).

Within limits, the two different modes can be combined, then the
mode icons will be displayed simultaneously. 
When the 

w

 icon is shown, the unit is activated and heating the

domestic water. When the 

w

 icon is blinking rapidly, the

powerful mode is active. When the 

w

 icon in blinking slowly, the

disinfection mode is active.
When the 

s

 icon is shown, the unit will work in quiet mode.

4.

EXTERNAL CONTROL ICON 

e

When the benefit kWh power rate signal is sent, the centralised
control indication 

e

 will appear to indicate that benefit kWh

power rate is active.

5.

DAY OF THE WEEK INDICATOR 

1234567

This indicator shows the current weekday.

When reading or programming the schedule timer, the indicator
shows the set day.

6.

CLOCK DISPLAY 

8

The clock display shows the current time.

When reading or programming the schedule timer, the clock
display shows the action time.

7.

SCHEDULE TIMER ICON 

p

This icon indicates that the schedule timer is enabled. When this
icon is blinking, it means the domestic hot water tank was not
heated up to the set point within the scheduled time (refer to the
field settings explained in the installation manual).

8.

ACTION ICONS 

q

These icons indicate the programming actions for each day of
the schedule timer.

9.

OFF ICON 

x

This icon indicates that the OFF action is selected when
programming the schedule timer.

10.

INSPECTION REQUIRED 

k

 and 

l

These icons indicate that inspection is required on the
installation. Consult your dealer.

11.

SET TEMPERATURE DISPLAY 

9

The display shows the current domestic water temperature .

12.

SETTING 

$

This icon appears when the scheduled program is saved.

13.

NOT AVAILABLE 

n

This icon is displayed whenever a function is restricted or a
function is not available.

14.

DEFROST MODE ICON 

d

This icon indicates that the defrost mode is active.

15.

COMPRESSOR ICON 

ç

-

This icon indicates that the compressor of the heat pump unit 
is active.

-

When freeze protection mode is active, this icon is blinking.

16.

BOOSTER HEATER ICON 

m

-

This icon indicates that the booster heater is active. The 
booster heater provides auxiliary heating for the domestic hot 
water tank (if a higher temperature than 60°C is needed) 
(refer to 

the field settings 

explained in the installation manual) 

or works as backup heating when the temperature in the 
installation room becomes too low.

-

When freeze protection mode is active, this icon is blinking.

The booster heater is located in the domestic hot water tank.

17.

PUMP ICON 

é

-

This icon indicates that the circulation pump is active.

-

When freeze protection mode is active, this icon is blinking.

18.

AMBIENT TEMPERATURE DISPLAY 

u

Refer to the installation manual.

19.

AUTO ADAPTIVE SET POINT ICON 

a

This icon indicates that the controller will adapt the temperature
set point automatically, based on the history of used domestic
hot water. (Example: when there was little use of domestic hot
water, the set point will automatically adapt to a lower set point.)
(Refer to "Auto adaptive set point operation" on page 9.)

20.

TEMPERATURE ICON 

b

This icon is displayed when the displayed value represents a
temperature.

The icon is also displayed when the temperature set point is set
in schedule timer programming mode.

21.

TEST OPERATION ICON 

t

This icon is not applicable with this unit.

22.

FIELD SET CODE 

;

-

This code represents the code from the field set list. Refer to 
the "Field settings table" on page 15.

-

This code also refers to the error code list and is for service 
purposes only. Refer to the error code list in the installation 
manual.

23.

ERROR CODE 

:

The three digits are used to display the indication codes while
consulting the actual temperatures. Refer to the installation
manual.

24.

AUTO ADAPTIVE SET POINT BUTTON 

ba

This button enables or disables the auto adaptive set point
function.

If the controller is set in permission level 3 (refer to "Field
settings" on page 13), the auto adaptiv
e set point button will not
be operable.

25.

INSPECTION/TEST OPERATION BUTTON 

z

This button is used for installation purposes and changing field
settings. Refer to "Field settings" on page 13.

26.

PROGRAMMING BUTTON 

<

This multi-purpose button is used to program the controller. The
function of the button depends on the actual status of the
controller or on previous actions carried out by the operator.

1

16

3

5

6

23

8

13

11

18

20

14

4

7

9

12
10

21

30

31

25

22

19

24

29
28

26

27

2

17

15

Содержание EKHHS200AA1V3

Страница 1: ...OPERATION MANUAL EKHVWQ002AAV3 EKHHS200AA1V3 EKHHS260AA1V3 Domestic hot water heat pump ...

Страница 2: ...ance activities 16 7 3 Standstill 16 8 Troubleshooting 17 9 Disposal requirements 17 The English text is the original instruction Other languages are translations of the original instructions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruc...

Страница 3: ...s a potentially hazardous situation which if not avoided may result in minor or moderate injury It may also be used to alert against unsafe practices NOTICE Indicates situations that may result in equipment or property damage accidents only INFORMATION This symbol identifies useful tips or additional information Electric current Danger of burning and scalding DANGER ELECTRICAL SHOCK Switch off all ...

Страница 4: ...nual 4 1 Domestic water heating operation quick start up Schedule timer operation Continuous operation Powerful operation INFORMATION Refer to the installation manual of the unit for installation procedures Icon p is displayed a a To display or remove the p icon press the pr button Schedule timer operation Push the ba button Push the Y button Push the Y button The 0 LED will light up and the unit ...

Страница 5: ...fers full control over your installation Basic controller functions The basic controller functions are Turning the unit ON OFF Schedule timer continuous mode Selection of features quiet mode refer to page 8 auto adaptive set point control refer to page 9 Temperature set point adjustment refer to page 6 Powerful mode The digital controller supports a power cut off of maximum 2 hours When autorestar...

Страница 6: ...ailable 14 DEFROST MODE ICON d This icon indicates that the defrost mode is active 15 COMPRESSOR ICON ç This icon indicates that the compressor of the heat pump unit is active When freeze protection mode is active this icon is blinking 16 BOOSTER HEATER ICON m This icon indicates that the booster heater is active The booster heater provides auxiliary heating for the domestic hot water tank if a hi...

Страница 7: ...e by 10 minutes 3 Use the wi or wj button to adjust the day of the week Each time the wi or wj button is pressed the next or previous day is displayed 4 Press the button to confirm the current set time and day of the week To leave this procedure without saving press the pr button If no button is pressed for 5 minutes the clock and day of the week will return to their previous setting Setting the sc...

Страница 8: ... command It is clear that the last programmed command may date from the day before Refer to Consulting programmed actions on page 12 INFORMATION Default the schedule timer is set as follows Time Set point temperature Sunday until thursday 7 4 22 6 h 45 C Friday and saturday 5 6 22 6 h 55 C If this does not fullfill the customers demands it has to be set as explained in Programming and consulting th...

Страница 9: ...he desired quiet mode is set through a field setting Refer to the field settings explained in the installation manual for a detailed description how to set one or more field settings Disinfection operation This mode will disinfect the domestic hot water tank by periodically heating the domestic water to a specific temperature During the operation of this mode the w icon will be blinking slowly with 0 ...

Страница 10: ...more actions are programmed for the same day and at the same time only the action with the lowest action number will be executed You can always alter add or remove the programmed actions later Example 1 Example 2 If on mondays the customer is usually at home and uses a lot of hot water the set point for monday will increase untill the required amount of hot water is reached as shown in the figure b...

Страница 11: ...s e g 4 and 5 are not displayed 7 Press the button for 5 seconds to enter the programming mode 8 Use the button to select the action number you would like to program or to modify 9 Use the pi and pj buttons to set the correct action time 10 Use the ba button to select x to switch heating and the controller off 9 set the temperature by means of the wi and wj buttons 11 Repeat steps 8 to 10 to progr...

Страница 12: ...rogramming mode 6 Use the button to select the action number you would like to program or to modify 7 Use the pi and pj buttons to set the correct action time 8 Use the ba button to select or deselect x as action 9 Repeat steps 6 to 8 to program the other actions of the selected mode When all actions have been programmed make sure that the display shows the highest action number you would like to ...

Страница 13: ...i e after pressing the button for 5 seconds press the pr button once You can now select another day by using the pi and pj buttons and restart consulting and programming Copying programmed actions to next day In heating mode program it is possible to copy all programmed actions of a specific day to the next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day p...

Страница 14: ...on If the P button is pressed the heat pump module heats up the domestic hot water tank as fast as possible to a predefined setpoint This means that the inverter compressor frequency will be higher then in normal operation mode and that sound level and power consumption can be higher This mode might be usefull when exceptional high hot water consumption depletes all the available domestic hot water...

Страница 15: ...ed defines whether the reheat operation is turned ON 1 or OFF 0 1 Automatic domestic hot water tank temperature set point calculation 1 00 Renewal time for set point calculation The automatic temperature set point calculation is done on a daily basis The algorithm calculates for each day of the week an optimum domestic hot water tank temperature set point To calculate this temperature setpoint the ...

Страница 16: ...lated setting 1 ON 02 Installation related setting 23 00 03 Installation related setting 0 OFF 04 Installation related setting 32 3 Miscellaneous 00 Installation related setting 1 ON 01 Installation related setting 3 02 Installation related setting 0 OFF 03 Installation related setting 0 OFF 4 Miscellaneous 03 Installation related setting 0 04 Installation related setting 1 6 Miscellaneous 00 Inst...

Страница 17: ...dissipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not at a dishwasher clothes washer or other appliance During this procedure there must be no smoking open flame or any electrical appliance operating nearby If hydrogen is discharged through the tap it will probably make a sound as of air escaping Each inspection has to be carried...

Страница 18: ...zed treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative consequences for the environment and human health Please contact the installer or local authority for more information NOTES POSSIBLE CAUSES CORRECTIVE ACTIONS No readings on the remote controller blank display Check if the mains power is still con...

Страница 19: ......

Страница 20: ...4PW65343 1A 10 2010 Copyright 2010 Daikin ...

Отзывы: