8.1.3.13 Defrosting
Defrosting is enabled:
Automatically, when the temperature of the
evaporator is below the temperature established in
parameter d17 (only if P4 has a value other than
0);
In any case, the compressor must have been left
switched on for a period either longer than or equal
to d18 minutes between two defrosting procedures.
Otherwise the request to enable the defrosting
procedure will not be accepted.
If P4 = 1, d2 represents the temperature of the
evaporator. The defrosting procedure terminates
when the temperature exceeds the temperatures
represented by d2.
If P4 = 0 or P4 = 2, parameter d2 is not taken into
consideration.
If during the defrosting procedure the evaporator or
thermistor is above the threshold set by parameters
d2 and P4 = 1, the request to enable the defrosting
procedure is not accepted.
The parameter d3 establishes the maximum
duration of the stage.
When defrosting mode is on, the heating
element will commence operation
If the “Anti-Legionella” or the “Overboost”
functions are in progress, the defrosting
procedure cannot be enabled.
8.1.3.14 Day and real time settings
Make sure that the keyboard is not locked
(paragraph 8.1.3.3) and that no other advanced
procedures are in progress;
Press and release the
key: the first available
code will appear on the display;
Press and release either the
or the
key
until “
rtc
” appears;
The day is displayed as 1...7 (number 1 corresponding
to Monday).
To change the day of the week:
Press and release the
key: the display will
show “
dd
” followed by two numbers representing
the day;
Press and release either the
or the
key
within the next 15 seconds.
To change the time:
Press and release the
key while changing the
day of the month: the display will show “
hh
”
followed by two numbers representing the time (in
24 hr. format);
Press and release either the
or the
key
within the next 15 seconds.
To change the minutes:
Press and release the
key while changing the
time: the display will show “
nn
” followed by two
numbers representing the minutes;
Press and release either the
or the
key
within the next 15 seconds;
Press and release the
key or do not carry out
any operations for 15 seconds;
To exit the procedure:
Press and release the
key until the
temperature established by parameter P5 appears
on the display or do not carry out any operations
for 60 seconds.
Alternatively:
Press and release the
key.
Prior to performing operations within timeslots,
you should have carried out the settings
relating to the day and the real time.