Nominal air capacity
m
3
/h
350÷500
Max. pressure head available
Pa
120
Motor protection
Internal thermal circuit breaker with automatic reset
Condenser
Wrapped externally, not in contact with water
Coolant
R134a
Load
g
900
900
900
Water storage
Water storage nominal capacity
l
196
250
242
Max. quantity of hot water that can
be used Vmax (
3
)
l
275
342
342
Coil for connection to solar thermal
power system
m
2
N/A
N/A
1.0 m
2
Cathodic protection
Mg AnodeØ26x400 mm 1 x Mg anodeØ26x250
mm
+
1 x Mg anodeØ26x250
mm
1 x Mg anodeØ26x250
mm
+
1 x Mg anode Ø26x400
mm
Insulation
50 mm high-density polyurethane foam
Defrosting
Active with Hot Gas valve
Dimensions
mm
H1714xD600xD
max
650
H2000xD600xD
max
650
H2000xD600xD
max
650
Transport weight
Kg
103
115
132
Sound power indoors Lw(A)
(
4
)
dB(A)
53
53
53
Automatic anti-Legionnella
disinfection cycle
(
5
)
YES
YES
YES
Maximum working pressure
Bar
7
7
7
(
1
) temperature of incoming air supply 7°C (6°C), temperature of boiler storage environment 20°C, water heated from 10°C to 55°C,
(according to UNI EN 16147-2011)
(
2
) measurements carried out according to UNI EN 12897-2006
(
3
) measurements carried out according to UNI EN 16147-2011
(
4
) measurements carried out according to EN 12102-2013
(
5
) automatic activation every 30 days of operation
Содержание EKHH2E200AAV3
Страница 3: ...Version Log Version code Description Date 4P509215 1 Document release 20 12 2017...
Страница 4: ...Page 4 20 12 2017 Version 1 0...
Страница 36: ...Page 36 20 12 2017 Version 1 0 Parameter description Code U M Min Max Default Notes RESERVED E9 0 2 0...
Страница 41: ......
Страница 42: ...Page 42 20 12 2017 Version 1 0 Nov 17...