background image

EKHBRD011~Y1

Indoor unit for air to water heat pump system and options

4PW60971-1

Operation manual

14

11

Press the 

<

  button for 5 seconds to store the programmed

actions.

If the 

<

  button is pressed when action number 3 is displayed,

actions 1, 2 and 3 are stored but 4 and 5 are deleted.

By pressing the 

pr

 button several times, you return to previous

steps in this procedure and 

fi

nally return to normal operation.

12

You automatically return to step 6, start again to program the
following day.

Consulting programmed actions

Consulting space heating, domestic water heating or quiet mode is
carried out as follows:

1

Press the 

<

 button to enter the programming/consulting mode.

2

Select the operation mode you would like to consult by means of
the 

pi

 and 

pj

 buttons.

The actual mode is blinking.

3

Press the 

<

 button to con

fi

rm the selected mode.

The actual day is blinking.

4

Select the day you would like to consult by means of the 

pi

and 

pj

 buttons.

The selected day is blinking.

5

Press the 

<

 button to con

fi

rm the selected day.

The 

fi

rst programmed action of the selected day appears.

6

Use the 

pi

  and 

pj

  buttons to consult the other

programmed actions of that day.

This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.

By pressing the 

pr

 button several times, you return to previous

steps in this procedure and 

fi

nally return to normal operation.

Tips and tricks

Programming the next day(s)

After con

fi

rming the programmed actions of a speci

fi

c day (i.e. after

pressing the 

<

 button for 5 seconds), press the 

pr

 button once. You

can now select another day by using the 

pi

 and 

pj

 buttons

and restart consulting and programming.

Copying programmed actions to next day

In space heating program it is possible to copy all programmed
actions of a speci

fi

c day to the next day (e.g. copy all programmed

actions from "

1

" to "

2

").

To copy programmed actions to the next day, proceed as follows:

1

Press the 

<

 button to enter the programming/consulting mode.

The actual mode is blinking.

2

Select the operation mode you would like to program by means
of the 

pi

 and 

pj

 buttons.

The actual mode is blinking.

You can leave programming by pressing the 

pr

 button.

3

Press the 

<

 button to con

fi

rm the selected mode.

The actual day is blinking.

4

Select the day you would like to copy to the next day by means
of the 

pi

 and 

pj

 buttons.

The selected day is blinking.

You can return to step 2 by pressing the 

pr

 button.

5

Press the 

<

 and 

pr

 buttons simultaneously for 5 seconds.

After 5 seconds the display will show the next day (e.g. "

2

" if "

1

"

was selected 

fi

rst). This indicates that the day has been copied.

You can return to step 2 by pressing the 

pr

 button.

Deleting one or more programmed actions

Deleting one or more programmed actions is done at the same time
as storing the programmed actions.

When all actions for one day have been programmed, make sure that
the display shows the highest action number you would like to save.
By pressing the 

<

 button for 5 seconds, you store all actions except

those with a higher action number than the one that is displayed.

E.g. when the 

<

  button is pressed when action number 3 is

displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted.

Deleting a mode

1

Press the 

<

 button to enter the programming/consulting mode.

2

Select the operation mode you would like to delete by means of
the 

pi

 and 

pj

 buttons.

The actual mode is blinking.

3

Press the 

<

  and 

ba

  button simultaneously for 5 seconds to

delete the selected mode.

Deleting a day of the week

1

Press the 

<

 button to enter the programming/consulting mode.

2

Select the operation mode you would like to delete by means of
the 

pi

 and 

pj

 buttons.

The actual mode is blinking.

3

Press the 

<

 button to con

fi

rm the selected mode.

The actual day is blinking.

4

Select the day you would like to delete by means of the 

pi

and 

pj

 buttons.

The selected day is blinking.

5

Press the 

<

  and 

ba

  button simultaneously for 5 seconds to

delete the selected day.

Operating the remote alarm option

An optional EKRP1HBA digital I/O PCB can be connected to the
indoor unit and be used to remotely monitor your system. This
address card offers 3 voltage free outputs:

Output 1 = THERMO ON/OFF 

this output will be enabled when your unit is in space heating
operation.

Output 2 = ALARM OUTPUT 

this output will be enabled when your unit is in error condition.

Output 3 = DOMESTIC HOT WATER MODE ON/OFF

this output will be enabled when your unit is in domestic water
heating operation.

For more details about the wiring connections of this option, refer to
the wiring diagram of the unit.

Operating the optional remote controller

If besides the main remote controller the optional remote controller is
installed as well, the main remote controller (master) can access all
settings while the second remote controller (slave) can not access
schedule settings and parameter settings.

Refer to the installation manual for more details.

NOTE

Returning to previous steps in this procedure is done
by pressing the 

pr

 button.

Содержание EKHBRD014ABV1

Страница 1: ...OPERATION MANUAL EKHBRD011ABV1 EKHBRD014ABV1 EKHBRD016ABV1 EKHBRD011ABY1 EKHBRD014ABY1 EKHBRD016ABY1 Indoor unit for air to water heat pump system and options...

Страница 2: ...es or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to...

Страница 3: ...e rp button See Automatic storage on page 7 The p icon will display Hot water will be produced at next scheduled action When water heat up starts the w icon will be blinking 1 second interval Manual s...

Страница 4: ...used For installation purposes only 13 NOT AVAILABLE n This icon is displayed whenever a non installed option is addressed or a function is not available A function not available can mean insufficien...

Страница 5: ...seconds the display will show to the actual room temperature 32 QUIET MODE BUTTON s This button enables or disables quiet mode If the controller is set to permission level 2 or 3 refer to Field setti...

Страница 6: ...oor temperatures will result in warmer water and vice versa The unit has a floating set point Activating this operation will result in a lower power consumption than use with a manually fixed leaving...

Страница 7: ...k function is turned ON 1 or OFF 0 2 01 Start time time at which setback is started 2 02 Stop time time at which setback is stopped 5 02 Leaving water setback temperature temperature drop Domestic wat...

Страница 8: ...storage temperature set point is reached It is a one time hot water making feature Selecting manual storage operation for domestic water heating 1 Push and hold the w button for 5 seconds to activate...

Страница 9: ...er Field settings on page 15 for a detailed description how to set one or more field settings 4 00 Status defines whether the disinfection function is turned ON 1 or OFF 0 4 01 Operation interval day...

Страница 10: ...multaneous demand of space heating and domestic water heating The unit can not perform domestic water heating and space heating at the same time If both modes are requested at the same time the unit w...

Страница 11: ...eating stays enabled When pushing the r p button The schedule timer for space heating and domestic water heating along with the quiet mode will be stopped and will not start again The schedule timer i...

Страница 12: ...tion 3 When both setback function and schedule timer are enabled A Setback function B ON OFF instruction t Time T Temperature set point Room temperature Leaving water temperature t 18 18 C 60 60 C 60...

Страница 13: ...e repeated on a weekly basis In the domestic water heating and quiet mode program depending on remote controller model 4 or 5 actions can be programmed per mode The same actions are repeated on a dail...

Страница 14: ...s the button for 5 seconds to store the programmed actions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted You automatically return to s...

Страница 15: ...step 2 by pressing the pr button 5 Press the and pr buttons simultaneously for 5 seconds After 5 seconds the display will show the next day e g 2 if 1 was selected first This indicates that the day h...

Страница 16: ...Press the z button for a minimum of 5 seconds to enter FIELD SET MODE The icon 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed to the right 1 2...

Страница 17: ...10 20 1 C 02 Set point at low ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 D...

Страница 18: ...age temperature 70 45 75 1 C 04 Automatic maximum hot water tank storage temperature 70 55 75 1 C C Leaving water temperature limits 00 Installation related setting 80 37 80 1 C 01 Installation relate...

Страница 19: ...yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance with relevant local and national legislation Units must b...

Страница 20: ...NOTES...

Страница 21: ...NOTES...

Страница 22: ...NOTES...

Страница 23: ......

Страница 24: ...4PW60971 1 Copyright 2010 Daikin...

Отзывы: