EKHBRD011~Y1
Indoor unit for air to water heat pump system and options
4PW60971-1
Operation manual
12
Programming and consulting the schedule timer
Programming the schedule timer is
fl
exible (you can add, remove or
alter programmed actions whenever required) and straightforward
(programming steps are limited to a minimum). However, before
programming the schedule timer, remind:
■
Familiarize yourself with the icons and the buttons. You will need
them when programming. Refer to "Remote controller buttons
and icons" on page 3.
■
Fill out the form at the very end of this manual. This form can
help you de
fi
ne the required actions for each day. Keep in mind
that:
-
In the space heating program, depending on remote
controller model 4 or 5 actions can be programmed per
weekday. The same actions are repeated on a weekly basis.
-
In the domestic water heating and quiet mode program,
depending on remote controller model 4 or 5 actions can be
programmed per mode. The same actions are repeated on a
daily basis.
■
Take your time to enter all data accurately.
■
Try to program the actions in a chronological way: start with
action 1 for the
fi
rst action and end with the highest number for
the last action. This is not a requirement but will simplify the
interpretation of the program later.
■
If 2 or more actions are programmed for the same day and at the
same time, only the action with the highest action number will be
executed.
Example:
■
You can always alter, add or remove the programmed actions
later.
Programming space heating
NOTE
Remote controller model: 4 actions
Remote controller model: 5 actions
Programmed actions
Executed actions
Time
(hour)
Temperature
(°C)
Time
(hour)
Temperature
(°C)
1
16:00
—
22
1
06:00
—
21
2
18:00
—
OFF
2
08:00
—
23
3
08:00
—
23
3
16:00
—
22
4
06:00
—
21
4
18:00
—
OFF
5
18:00
—
26
5 sec
5 sec
Содержание EKHBRD014ABV1
Страница 20: ...NOTES...
Страница 21: ...NOTES...
Страница 22: ...NOTES...
Страница 23: ......
Страница 24: ...4PW60971 1 Copyright 2010 Daikin...