Installer reference guide
71
EHVH/X16
Daikin Altherma - Low Temperature Split
4P313777-1 – 2012.05
14 Technical data
*RLQ(04/06/08)* *R*Q(011/014/016)*V3 *R*Q(011/014/016)*W1
*HB(H/X)(04/08)CA# *HB(H/X)16CA#
*HB(H/X)16CA#
3V /
9W 9W 9W
3V /
9W
9W
9W
3V / 9W
9W
9W
1~
230V
3~
400V
3~
230V
1~
230V
3~
400V
3~
230V
1~
230V
3~
400V
3~
230V
3 / 6
kW
6 / 9
kW
6
kW
3 / 6
kW
6 / 9
kW
6
kW
3 / 6
kW
6 / 9
kW
6
kW
1~ 1
1
-
-
1
1
-
-
1
-
1
-
-
1 - - 1 - 1 - -
- 1 1 - 1 - 1 1
1~ 2
1
1
2
1
1
1
-
-
- 1
1 1
- 1 - - -
- - 1 1 -
- - -
- -
- 1 1
- 1 1 -
1 1
4D078288
* electrical meter specification
- pulse meter type/voltage free contact for 5 VDC detection by PCB
- possible number of pulse:
0.1 pulse/kWh
1pulse/kWh
10pulse/kWh
100 pulse/kWh
1000 pulse/kWh
- pulse duration:
minimum On time 40ms
minimum OFF time 100ms
- measurement type (depending on installation):
single phase AC meter
three phase AC meter (balanced loads)
three phase AC meter (unbalanced loads)
* electrical meter installation guideline
- General: it is the reponsability of the installer to cover the complete power consumption with electrical meters
(combination of estimation and metering is not allowed)
- Required number of electrical meters:
Outdoor unit type
Indoor unit type
Backup heater type
(#)
Backup heater
power supply
Backup heater
configuration
Electrical
meter type
Electrical
meter type
3~ balanced
3~ unbalanced
Benefit kWh rate power supply
Regular kWh rate power supply
3~ balanced
3~ unbalanced
A1P
Main PCB
A2P
User interface PCB
A3P
*
Solar pump station PCB
A3P
*
On/OFF thermostat (PC=power circuit)
A3P
*
Heat pump convector
A4P
*
Digital I/O PCB
A4P
*
Receiver PCB (Wireless On/OFF
thermostat)
A7P
Pump driver PCB (only for EHBH/X04+08
and EHVH/X04+08)
A8P
*
Demand PCB
B1L
Flow sensor
BSK
*
Solar pump station relay
DS1(A8P)
*
DIP switch
E1H
Backup heater element (1 kW)
E2H
Backup heater element (2 kW)
E3H
Backup heater element (3 kW)
E4H
*
Booster heater (3 kW)
F1B
Overcurrent fuse backup heater
F2B
*
Overcurrent fuse booster heater
F1T
Thermal fuse backup heater
F1U, F2U
*
Fuse 5 A 250 V for digital I/O PCB
FU1
Fuse T 6.3 A 250 V for PCB
PHC1
*
Optocoupler input circuit
K1M, K2M
Contactor backup heater
K3M
*
Contactor booster heater
K5M
Safety contactor backup heater (only for
*9W)
K*R
Relay on PCB
M1P
Main supply pump
M2P
# Domestic hot water pump
M2S
# 2-way valve for cooling mode
M3S
(*) 3-way valve for floor heating/domestic hot
water
Q1DI, Q2DI
# Earth leakage circuit breaker
Q1L
Thermal protector backup heater
Q2L
*
Thermal protector booster heater
R1T
Outlet water heat exchanger thermistor
R1T (A2P)
Ambient sensor user interface
R1T (A3P)
*
Ambient sensor On/OFF thermostat