EHVH/X16
Daikin Altherma - Low Temperature Split
4P313777-1 – 2012.05
Installer reference guide
2
1 About the documentation
11 Maintenance and service
56
11.1 Overview: Maintenance..................................................................56
11.2 Maintenance safety precautions ....................................................56
11.2.1 Opening the indoor unit ......................................................56
11.3 Checklist for yearly maintenance for indoor unit ............................56
11.3.1 To drain the domestic hot water tank..................................57
12 Troubleshooting
57
12.1 Overview: Troubleshooting.............................................................57
12.2 General guidelines .........................................................................57
12.3 Solving problems based on symptoms ..........................................57
12.3.1 Symptom: The unit is NOT heating or cooling as
expected .............................................................................57
12.3.2 Symptom: The compressor does NOT start (space heating
or domestic water heating) .................................................58
12.3.3 Symptom: The pump is making noise (cavitation)..............58
12.3.4 Symptom: The pressure relief valve opens ........................58
12.3.5 Symptom: The water pressure relief valve leaks................58
12.3.6 Symptom: The space is NOT sufficiently heated at low
outdoor temperatures .........................................................58
12.3.7 Symptom: The pressure at the tapping point is temporarily
unusual high .......................................................................59
12.3.8 Symptom: Decoration panels are pushed away due to a
swollen tank........................................................................59
12.4 Solving problems based on error codes.........................................59
12.4.1 Error codes: Overview ........................................................59
13 Glossary
60
14 Technical data
61
14.1 Dimensions and service space ......................................................61
14.1.1 Dimensions and service space: Indoor unit........................61
14.2 Components...................................................................................63
14.2.1 Components: Indoor unit ....................................................63
14.2.2 Components: Switch box (indoor unit)................................64
14.3 Functional diagrams.......................................................................65
14.3.1 Functional diagram: Indoor unit ..........................................65
14.4 Piping diagram ...............................................................................66
14.4.1 Piping diagram: Indoor unit.................................................66
14.5 Wiring diagram ...............................................................................67
14.5.1 Wiring diagram – components: Indoor unit.........................67
14.6 Technical specifications..................................................................73
14.6.1 Technical specifications: Indoor unit ...................................73
14.7 Operation range .............................................................................75
14.7.1 Operation range: Indoor unit...............................................75
14.8 ESP curve ......................................................................................78
14.8.1 ESP curve: Indoor unit........................................................78
14.9 Performance...................................................................................79
14.10Combination table ..........................................................................82
1
About the documentation
1.1
About this document
Target audience
Authorized installers
Documentation set
This document is part of a documentation set. The complete set
consists of:
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
2
General safety precautions
2.1
About the documentation
Q
The original documentation is written in English. All other
languages are translations.
Q
The precautions described in this document cover very
important topics, follow them carefully.
Q
All activities described in the installation manual must be
performed by an authorized installer.
2.1.1 Meaning of warnings and symbols
Document
Contains…
Format
General
safety
precautions
Safety instructions that
you must read before
installing
Paper (in the box of the
indoor unit)
Indoor unit
installation
manual
Installation instructions
Outdoor unit
installation
manual
Installation instructions
Paper (in the box of the
outdoor unit)
Installer
reference
guide
Preparation of the
installation, technical
specifications, good
practices, reference
data,…
CD/DVD in the box of the
indoor unit)
Addendum
book for
optional
equipment
Additional info about how
to install optional
equipment
Paper (in the box of the
indoor unit)
CD/DVD (in the box of the
indoor unit)
DANGER
Indicates a situation that results in death or serious injury.
DANGER: RISK OF ELECTROCUTION
Indicates a situation that could result in electrocution.
DANGER: RISK OF BURNING
Indicates a situation that could result in burning because of
extreme hot or cold temperatures.
WARNING
Indicates a situation that could result in death or serious
injury.
CAUTION
Indicates a situation that could result in minor or moderate
injury.
NOTICE
Indicates a situation that could result in equipment or
property damage.
INFORMATION
Indicates useful tips or additional information.
Содержание EHVH16S18CA
Страница 84: ...4P313777 1 2012 05 Copyright 2012 Daikin ...