ESIE13-03
|
Part 3. Repair
2. Unit specific repair procedures
Page 92
13/05/15
|
Version 2.0
Ground source heat pump
2.2. Parts replacement procedures
Overview of parts replacement procedures:
2.2.1. Removing the lower rear panel
2.2.1.1 Preliminary actions
1. Switch off the Daikin Altherma GSHP via the user interface.
2. Shut off and disconnect the brine piping.
3. Shut off and disconnect the space heating piping.
4. Shut off and disconnect the domestic hot water piping.
5. Remove the front panel, refer to
"Removing the front panel" on page 85
.
6. Drain the domestic hot water tank, refer to
"Draining the domestic hot water tank" on page 88
7. Drain the brine circuit, refer to
"Draining the brine circuit" on page 86
8. Pull the Daikin Altherma GSHP from the wall to gain access to the rear panel.
2.2.1.2 Procedure
Removal
1. Loosen and remove the 8 screws (1) that fix the (lower) rear panel (2).
2. Remove the lower rear panel (2) while guiding the brine drain hose (3) and the domestic hot water drain hose (4) through the
opening in the (lower) rear panel (2).
Removing the lower rear panel.......................................................92
Replacing a PCB in the switch box.................................................93
Cleaning the brine filter...................................................................98
Cleaning the water filter................................................................ 100
Replacing the brine flow switch .................................................... 102
Replacing the water flow sensor................................................... 104
Replacing the brine pump............................................................. 105
Replacing the backup heater........................................................ 106
Replacing the thermal protector backup heater............................ 109
Replacing the water pressure relief valve..................................... 110
Replacing the brine pressure relief valve ..................................... 113
Replacing the water pump............................................................ 115
Replacing the compressor............................................................ 119
Replacing the water expansion vessel .........................................123
Replacing the brine expansion vessel ..........................................124
Replacing the 3-way valve motor..................................................125
Replacing the 3-way valve body ...................................................128
Replacing the water manometer...................................................129
Replacing the brine manometer....................................................131
Replacing the electronic expansion valve K1E body ....................133
Replacing the electronic expansion valve K1E electromagnet .....135
Replacing the refrigerant high pressure sensor............................137
Replacing the refrigerant high pressure switch.............................140
Replacing a thermistor (except R10T) ..........................................143
Replacing temperature sensor R10T............................................145