ESIE13-03
|
Part 3. Repair
2. Unit specific repair procedures
Page 128
13/05/15
|
Version 2.0
Ground source heat pump
3. Proceed in reverse order.
4. Fill the domestic hot water circuit.
Figure 48 - Replacing the 3-way valve motor - 4
2.2.17. Replacing the 3-way valve body
2.2.17.1 Preliminary actions
1. Switch off the Daikin Altherma GSHP via the user interface.
2. Remove the front panel, refer to
"Removing the front panel" on page 85
.
3. Remove the top panel, refer to
"Removing the top panel" on page 88
4. Drain the water circuit, refer to
"Draining the water circuit" on page 87
5. Separate the 3-way valve motor from the 3-way valve, refer to
"Replacing the 3-way valve motor" on page 125
2.2.17.2 Procedure
Removal
1. Remove the 3 clips
from the 3-way valve body
2. Remove the 3-way valve body
.
1. 3-way valve knob
3. Notch
2. 3-way valve axle
DOMESTIC HOT WATER
SPACE HEATING
1
3
2
1
3
2