IM 1229-1 • INTELLIGENT EQUIPMENT 3 

www.DaikinApplied.com

I

nTroduCTIon

I

nTroduCTIon

Reference Documents

Number

Company

Title

Source

OM 1218

Daikin Applied

Operation and 

Maintenance Manual www.daikinapplied.com

IM 1219

Daikin Applied

Installation Manual

www.daikinappled.com

Limited Warranty

Consult your local Daikin Representative for warranty 

details. Refer to Form 933-43285Y. To find your local Daikin 

representative, go to 

www.DaikinApplied.com

.

Notice

© 2015 Daikin Applied, Minneapolis MN. All rights reserved 

throughout the world.
Daikin reserves the right to change any information contained 

herein without prior notice. The user is responsible for 

determining whether this software is appropriate for his or her 

application.

General Information

This manual contains the information you need to replace 

an existing gateway for the Intelligent Equipment solution. 

For installation Technical Support, please contact the Daikin 

Applied Controls Support Group at (866) 462-7829.

Hazard Identification Messages

Recognize Safety Symbols, Words and Labels

The following symbols and labels are used throughout this 

manual to indicate immediate or potential hazards. It is the 

owner and installer’s responsibility to read and comply with 

all safety information and instructions accompanying these 

symbols. Failure to heed safety information increases the 

risk of property damage and/or product damage, serious 

personal injury or death. Improper installation, operation and 

maintenance can void the warranty.

 

DANGER

Dangers  indicate  a  hazardous  situation  which  will  result  in 

death or serious injury if not avoided.

 WARNING

Warnings indicate potentially hazardous situations, which can 

result in property damage, severe personal injury, or death if 

not avoided.

 CAUTION

Cautions indicate potentially hazardous situations, which can 

result in personal injury or equipment damage if not avoided.

 WARNING

Electric shock hazard . Can cause personal injury or 

equipment damage .

This equipment must be properly grounded. Connections and 

service to the MicroTech III Air Handling Unit Controller and 

Machine-to-Machine Gateway must be performed only by 

personnel knowledgeable in the operation of the equipment 

being controlled.

 CAUTION

Static sensitive components . Can cause equipment 

damage .

Discharge  any  static  electrical  charge  by  touching  the  bare 

metal inside the control panel before performing any service 

work. Never unplug cables, circuit board terminal blocks, or 

power plugs while power is applied to the panel.

 NOTICE

This  equipment  generates,  uses  and  can  radiate  radio 

frequency energy and, if not installed and used in accordance 

with this instruction manual, may cause interference to radio 

communications. It has been tested and found to comply with 

the limits for a Class A digital device, pursuant to part 15 of the 

FCC rules. These limits are designed to provide reasonable 

protection against harmful interference when the equipment 

is operated in a commercial environment. Operation of this 

equipment  in  a  residential  area  is  likely  to  cause  harmful 

interference in which case the user will be required to correct 

the interference at his or her own expense. 

Daikin disclaims 

any liability resulting from any interference or for the 

correction thereof .

Содержание DPS

Страница 1: ...tion and Maintenance Manual IM 1229 1 Group Controls Part Number 910159718 Date November 2015 Replacement Intelligent Equipment Gateway Commercial Rooftop Models DPS and MPS Applied Rooftop Models RDS...

Страница 2: ...Machine to Machine M2M Gateway 4 Unpacking 4 Material shipped loose 4 Removal and Installation Instructions 5 Necessary Tools 5 Removal 5 Disconnecting Existing Wiring Interconnections 5 Installation...

Страница 3: ...a hazardous situation which will result in death or serious injury if not avoided WARNING Warnings indicate potentially hazardous situations which can result in property damage severe personal injury...

Страница 4: ...and CRM data to a user device smart phone tablet etc via wireless Wi Fi cellular or local area network LAN connection This manual contains instructions specific to replacing an existing machine to ma...

Страница 5: ...inside the control panel before performing any service work Never unplug cables circuit board terminal blocks or power plugs while power is applied to the panel CAUTION Sharp edges on sheet metal and...

Страница 6: ...the M2M Gateway receptacle marked Power Input Figure 3 Figure 3 M2M Power Input Antenna and Ethernet Connections Depending on the application the M2M Gateway could be connected to the cloud via cellu...

Страница 7: ...of the existing Gateway on the mounting bracket The new M2M Gateway must be installed in the same orientation Remove the existing Gateway by unscrewing the 5 16 head sheet metal screws located at the...

Страница 8: ...nter the unique password that was provided with the Gateway hardware and press ENTER c This opens the Gateway home page 3 Click the System tab Figure 7 a Select the Settings tab b Under Time Zone veri...

Страница 9: ...IM 1229 1 INTELLIGENT EQUIPMENT 9 www DaikinApplied com System Set Up Figure 7 System Tab Figure 8 Time Updated to Time Zone Figure 9 Keypad Controls Figure 10 Date Time Schedules Menu...

Страница 10: ...ore information on how to change your computer s IP settings consult the Operating System s Help files d Temporarily disable the wireless adapter s on the computer as these may prevent accessing the H...

Страница 11: ...IM 1229 1 INTELLIGENT EQUIPMENT 11 www DaikinApplied com System Set Up Figure 11 M2M Gateway Home Page Figure 12 Verify Cellular Signal Strength...

Страница 12: ...ay home page Figure 13 4 If the M2M Gateway will be using DHCP skip to step 6 If the M2M Gateway will be using a Static IP address go to step 5 5 Click the Network tab a Under wlan0 Configuration Figu...

Страница 13: ...IM 1229 1 INTELLIGENT EQUIPMENT 13 www DaikinApplied com System Set Up Figure 13 M2M Gateway Home Page Figure 14 Wireless LAN Configuration...

Страница 14: ...IM 1229 1 INTELLIGENT EQUIPMENT 14 www DaikinApplied com System Set Up Figure 15 Wireless Configuration Screen Figure 16 Wireless Signal Strength...

Страница 15: ...to match the subnet c Navigate to your laptop s Local Area Connection settings screen and change the IP subnet mask to 255 255 0 0 and the IP address to be compatible with the default M2M Gateway IP a...

Страница 16: ...this can take as much as two minutes 16 Confirm that ICMP host of wan interface is still set to disable a If so go to step 17 b If not set to disable c Click Save changes button i IMPORTANT Allow the...

Страница 17: ...IM 1229 1 INTELLIGENT EQUIPMENT 17 www DaikinApplied com System Set Up Figure 18 WAN Configuration Settings Figure 19 Add New Interface Selection...

Страница 18: ...IM 1229 1 INTELLIGENT EQUIPMENT 18 www DaikinApplied com System Set Up Figure 20 M2M Gateway Home Page Figure 21 WAN Configuration Settings...

Страница 19: ...magnetic base Check antenna connection to WLAN connection on Gateway Check signal strength through WebIF Verify Wi Fi IP addressing ESSID and login credentials match customer supplied Wireless LAN re...

Страница 20: ...nt to its standard terms and conditions of sale including Limited Product Warranty Consult your local Daikin Applied representative for warranty details To find your local Daikin Applied representativ...

Отзывы: