background image

QUATTRO

INSTALLATION 

MANUAL

Follow all safety codes.

Wear safety glasses and work gloves.

Before installing or performing maintenance or service  on the purifier, turn 

off unit and disconnect from power source. Electrical shock can cause 

injury or death. There may be more than one disconnect switch.

Never expose eyes or skin to ultraviolet light from any source. The purifier 

MUST BE DISCONNECTED from power source before performing 

maintenance or service. Personal injury may result.

Do not touch lamp glass without gloves. Reduced performance of lamp 

may result. Clean lamp after handling.

The UV lamp contains a small quantity of mercury.  If a lamp breaks, clean 

and dispose of with care.

Use only specified replacement lamps with your purifier.  Use of an 

incorrect lamp can result in damage  to the purifier and/or lamp.

UV rays may destroy certain types of filters (polymer or plastic), please 

keep unit away from shining directly on plastic.

Serial Number# _____________________

Date Installed: ______________________

Installed By: ________________________

Installers’ Contact Info.: ______________
___________________________________
___________________________________

UV lamp can be disposed/recycled after use as for any other fluorescent bulb. 

WARNING

PLEASE SAVE FOR YOUR RECORDS

NOTICE

SANUVOX TECHNOLOGIES INC. © 2020

1-888-SANUVOX   www.sanuvox.com

Содержание Quattro

Страница 1: ...after handling The UV lamp contains a small quantity of mercury If a lamp breaks clean and dispose of with care Use only specified replacement lamps with your purifier Use of an incorrect lamp can result in damage to the purifier and or lamp UV rays may destroy certain types of filters polymer or plastic please keep unit away from shining directly on plastic Serial Number ______________________ Da...

Страница 2: ...out your home or facility Sanuvox systems have been tested by the EPA Environmental Protection Agency the National Homeland Security Research Center medical universities and lndependent 3rd party laboratories THIS BOX CONTAINS 1 QUATTRO 4 18 Straight UV Lamps A Vacuum Sensor Elbow B Adjustable Clutch Litterature Package 1 Lamp Date Decal 1 Warranty Card Drill Pair of Snips Saw OR 1 Pair of Gloves ...

Страница 3: ...vacuum sensor to function properly If the QUATTRO is to be installed in a horizontal position see Figure C or the differential is not sufficient the vacuum sensor must be bypassed and the QUATTRO is to be wired into the fan circuit To bypass the vacuum sensor disconnect the two leads on the pressure switch and joining them together with a wire nut and wiring the QUATTRO into the fan circuit or the...

Страница 4: ...ED will be OFF corresponding to lamp out If both LED lights are OFF the ballast is not functioning If none of the 8 LED lights are lit then there is not enough of a vacuum differential to activate the vacuum switch or the vacuum switch is defective Fiberglass or paper filter media are recommended for operation of HVAC when filters are exposed to direct line of sight with the ultraviolet light Poly...

Отзывы: