Installation Instructions for

DP5HH 15.2 SEER2 “H” Series Self-contained Package Air 

Conditioners and Heat Pump Units With R-410A

IOD-3023

12/2021

Only personnel that have been trained to install, adjust, 

service or repair(hereinafter, “service”) the equipment 

specified in this manual should service the equipment.  The 

manufacturer will not be responsible for any injury or 

property damage arising from improper service or service 

procedures. If you service this unit, you assume responsi-

bility for any injury or property damage which may result. 

In addition, in jurisdictions that require one or more 

licenses to service the equipment specified in this manual, 

only licensed personnel should service the equipment. 

Improper installation, adjustment, servicing or repair of 

the equipment specified in this manual, or attempting to 

install, adjust, service or repair the equipment specified in 

this manual without proper training may result in product 

damage, property damage, personal injury or death.

WARNING

ATTENTION INSTALLING PERSONNEL

Prior to  installation, thoroughly familiarize yourself with this 

Installation Manual. Observe all safety warnings. During 

installation or repair, caution is to be observed.

It is your responsibility to install the product safely and to 

educate the customer on its safe use.

  

RECOGNIZE THIS SYMBOL

  AS A SAFETY PRECAUTION.

These installation instructions cover the outdoor installation 

of self contained package air conditioner and heating units. 

See the Specification Sheets applicable to your model for 

information regarding accessories.

*NOTE:

 Please contact your distributor or our website for 

the applicable Specifications Sheets referred to in this 

manual.

Table of Contents

TO THE INSTALLER .........................................................2

SHIPPING INSPECTION ...................................................2

  Checking Product Received .......................................2

  Message to the Homeowner .......................................2

REPLACEMENT PARTS ...................................................2

  Ordering Parts .............................................................2

IMPORTANT SAFETY INSTRUCTIONS ...........................2

  Recognize Safety Symbols, Words, and Labels ....2

CODES AND REGULATIONS .........................................

3

  General ..........................................................................

3

  EPA Regulations ...........................................................

3

  National Codes .............................................................

3

MAJOR COMPONENTS ....................................................

3

  General ..........................................................................

3

INSTALLATION ..................................................................4

  Pre-Installation Checkpoints ....................................4

  Clearance ......................................................................4

  Location .........................................................................4

  Outside Slab Installation  .........................................4

  Rooftop Installation  ..................................................4

INSTALLATION INSTRUCTIONS

Our continuing commitment to quality products may mean a change in specifications without notice. 

© 2021 

19001 Kermier Rd. Waller, Tx 77484

www.daikincomfort.com

WARNING

Do not bypass safety devices.

Содержание DP5HH2441 Series

Страница 1: ...ourself with this Installation Manual Observe all safety warnings During installation or repair caution is to be observed It is your responsibility to install the product safely and to educate the cus...

Страница 2: ...24 hours prior to compressor start up to ensure crankcase heater has sufficiently warmed the compressor Compressor damage may occur if this step is not followed Before using this manual check the seri...

Страница 3: ...ct work The units can also be easily converted to accommodate a plenum for normal or low static applications The DP C DP H series are self contained packaged units so the only connections needed for i...

Страница 4: ...the unit be placed so that condenser air discharge does not blow toward windows less than 25 feet away The unit should be set on a solid level foundation preferably a concrete slab at least 4 inches...

Страница 5: ...rter Your distributor has a factory designed square to round converter transition The model s of these kits are as follows Small Chassis 25 SQRPCH101 Medium Chassis 27 5 SQRPCH102 Large and Extra Larg...

Страница 6: ...ty of sufficient power to operate the unit The voltage frequency and phase at the power supply should be checked to make sure it corresponds to the unit s RATED VOLTAGE REQUIREMENT Install a branch ci...

Страница 7: ...gth of the run can be determined from Table 4 using the circuit ampacity found on the unit rating plate From the unit disconnect to unit the smallest wire size allowable in Table 4 may be used for the...

Страница 8: ...ndoor return air until the unit trips 13 If unit operates properly in the heating cycle raise the temperature setting until the heating second stage makes contact Supplemental resistance heat if insta...

Страница 9: ...used to prevent full electric heater operation at varying outdoor ambient 0 F to 45 F They are normally open above their set points and closed below to permit staging of indoor supplement heater oper...

Страница 10: ...ostat calls for heat At the end of the timing period the unit s defrost cycle will be initiated provided the sensor remains closed When the sensor opens approximately 60 5 F the defrost cycle is termi...

Страница 11: ...ll use the higher speed setting NOTE GPC15 and GPH16 units are rated for a maximum E S P of 0 8 except when using a 20kw electric heater The maximum static for 20 kW electric heat is 0 5 E S P When th...

Страница 12: ...d small line near liquid line access fitting with adequate contact and insulate for best possible reading 3 Check subcooling and superheat Two stage systems running on low stage with TXV application s...

Страница 13: ...clean and sufficient air volume must pass through the indoor coil to prevent excessive discharge pressure and high pressure cut out Outside Air Into Return Duct Do not introduce cold outside air into...

Страница 14: ...M 1645 1602 1560 1517 1475 1433 1390 1347 Watts 285 297 309 321 333 346 358 370 CFM 1239 1184 1146 1091 1049 1001 948 890 Watts 152 163 175 184 194 205 220 235 CFM 1837 1789 1748 1706 1665 1623 1577 1...

Страница 15: ...ssor stuck grounded or open winding open internal overload b Wait at least 2 hours for overload to reset If still open replace the compressor c Low voltage connection c At compressor terminals voltage...

Страница 16: ...minum Indoor Coil Cleaning Qualified Servicer Only This unit is equipped with an aluminum tube evaporator coil The safest way to clean the evaporator coil is to simply flush the coil with water This c...

Страница 17: ...Type NG Natural Gas LP Liquid Propane Residential Package Outdoor Section ELECTRICAL Supply Voltage Measure L1 and L2 Voltage L1 L2 Compressor Amps Condenser Fan Amps PRESSURES TEMPERATURES Suction Ci...

Страница 18: ...18 THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 19: ...19 THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 20: ...he feedback page PRODUCT REGISTRATION Thank you for your recent purchase Though not required to get the protection of the standard warranty registering your product is a relatively short process and e...

Отзывы: