32
U
PRIGHT
I
NSTALLATIONS
Depending on the installation and/or customer preference,
differing filter arrangements can be applied. Filters can be
installed in the central return register or a side panel external
filter rack kit (upflows). As an alternative a media air filter
or electronic air cleaner can be used as the requested filter.
Consider installing an air cleaner with deep-pleated media
filter at the time of furnace installation. A deep-pleated
filter with a MERV rating of 8 (minimum) will often provide
better filtration to protect equipment and the air distribution
system than a standard 1" filter and often has lower static
pressure loss than a 1" filter. Also a deep-pleated filter will
typically require less frequent replacement intervals. Avoid
using highly restrictive 1" filters which produce static
pressure loss greater than .25" W.C. In some installations
the minimum filter size required will not lend itself to a
filter installation on the side of the furnace. The installation
of a centrally installed air cleaner cabinet or a return duct
filter installation may offer more practicality.
Clean Comfort™ brand MERV 11 air cleaners have 5¼”
media filters and are available in the following configura-
tions. Consult your distributor for information on our
complete line of IAQ Clean Comfort™ products.
Air Cleaner Installation
Location
Maximum Heating
Airflow
Filter (Media)
Dimensions
Part Number
Air Cleaner
Family
Si de or bottom return
1200 CFM
16 i n X 20 i n x 5¼"
AM11-1620-5
Si de or bottom return
1600 CFM
16 i n X 25 i n x 5¼"
AM11-1625-5
Si de or bottom return
1600 CFM
20 i n X 20 i n x 5¼"
AM11-2020-5
Si de or bottom return
2000 CFM
20 i n X 25 i n x 5¼"
AM11-2025-5
Si de return
(for 2 s epara te returns )
Si de return (Ri ght a ngl e)
2000 CFM
20 i n X 25 i n x 5¼"
AM11-2025-5RA
AM11-5RA
Bottom return (pl atform)
2000 CFM
20 i n X 25 i n x 5¼"
AM11-2832-5PP
Bottom return (pl atform)
2000 CFM
20 i n X 25 i n x 5¼"
AM11-2843-5PP
AM11-5PP
AM11-5
2 X 1600 CFM
2, 16 i n X 25 i n x 5¼"
AM11-3225-5
AM11-3225
AM11-5
Family
AM11-5RA
Family
AM11-5PP
Family
The following figure shows possible filter locations.
FI
LT
E
R
AIR FLOW
CENTRAL
RETURN
GRILLE
FI
LT
E
R
SIDE RETURN
EXTERNAL FILTER
RACK KIT
(EITHER SIDE)
Possible Upright Upflow
Figure 44
FILT
ER
AIR FLOW
CENTRAL
RETURN
GRILLE
RETURN
DUCT
FI
LT
ER
FILTER
SUPPORT
BRACKET
(Field Supplied)
FILTER
ACCESS
DOOR
Possible Upright Counterflow
Filter Locations
Figure 45
H
ORIZONTAL
I
NSTALLATIONS
Filters must be installed in either the central return register
or in the return air duct work.
S
TARTUP
P
ROCEDURE
& A
DJUSTMENT
Furnace must have a 115 VAC power supply properly connected
and grounded. Proper polarity must be maintained for correct
operation. In addition to the following start-up and
adjustment items, refer to further information in
Operational
Checks