SYSTEM OPERATION
51
ComfortNet™ System
F
URNACE
A
DVANCED
F
EATURES
M
ENUS
Submenu Item
Indication/User Modifiable Options
Comments
Fault 1 (FAULT #1)
Most recent furnace fault
For display only
Fault 2 (FAULT #2)
Next most recent furnace fault
For display only
Fault 3 (FAULT #3)
Next most recent furnace fault
For display only
Fault 4 (FAULT #4)
Next most recent furnace fault
For display only
Fault 5 (FAULT #5)
Next most recent furnace fault
For display only
Fault 6 (FAULT #6)
Least recent furnace fault
For display only
Clear Fault History (CLEAR)
NO or YES
Selecting “YES” clears the
fault history
NOTE:
Consecutively repeated faults are shown a maximum of 3 times.
DIAGNOSTICS
Submenu Item
Indication (for Display Only; not User Modifiable)
Model Number (MOD NUM)
Displays the furnace model number
Serial Number (SER NUM)
Displays the furnace serial number (Optional)
Software (SOFTWARE)
Displays the application software revision
IDENTIFICATION
Submenu Item
User Modifiable Options
Comments
Heat Airflow Trim (HT
TRM)
-10% to +10% in 2% increments,
default is 0%
Trims the heating airflow by the selected
amount.
Heat ON Delay (HT ON
5, 10, 15, 20, 25, or 30 seconds,
default is 30 seconds
Selects the indoor blower heat ON delay
Heat OFF Delay (HT OFF)
30, 60, 90, 120, 150, or 180
seconds, default is 150 seconds
Selects the indoor blower heat OFF delay
Heat Airflow (HT ADJ)
1, 2, 3, or 4
Selects the nominal heating airflow (see
Startup Procedure and Adjustment –
Circulator Blower Speeds
for additional
information)
SET-UP