3
|
Components
Service manual
124
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01D – 2022.02
To install the thermistor
Indoor unit air (room) thermistor
As the indoor unit air (room) thermistor is located on the display PCB, install the
display PCB as described in the steps below:
1
Install the display PCB in the correct location on the unit.
2
Connect the connector to the display PCB.
Other refrigerant side thermistors
1
Install the thermistor in the thermistor holder as follows:
▪
For outdoor unit air (ambient) thermistor:
Correctly install the thermistor in the holder and close the thermistor holder.
▪
For refrigerant piping thermistors:
Pull the clip and install the thermistor in the specific thermistor holder. Make
sure the clip is in the correct position (blocking the thermistor).
c
a
b
e
d
f
f
a
Clip
b
Thermistor
c
Thermistor holder
d
Insulation
e
Thermistor wire
f
Tie strap