3
|
Components
Service manual
108
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01D – 2022.02
2
Remove 2 screws (class 20~35) or 3 screws (class 50~71) from the front grille.
3
Remove 2 screws from the front grille.
4
Push down the 3 upper hooks marked with a symbol with 3 circles.
a
b
a
a
Upper hook
b
Symbol with 3 circles
5
We recommend opening the flap before removing the front grille.
6
Place both hands under the centre of the front grille, push it up and then
toward you.
1
2
To remove the electrical wiring box cover
TO OPEN THE SERVICE COVER
1
Remove 1 screw from the service cover.
2
Pull out the service cover horizontally away from the unit.
a
b
a
Service cover screw
b
Service cover
a
b
a
Service cover screw
b
Service cover
NOTICE
When closing the service cover, make sure that the tightening torque does NOT
exceed 1.4 (±0.2) N•m.