3
|
Components
Service manual
110
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01D – 2022.02
d
Switch box screw
e
Switch box
5
Disconnect the connectors of the indoor unit fan motor, the swing flap motor
and the swing raster motor (if equipped) from the indoor unit PCB.
6
Remove the screw and remove the switch box from the indoor unit.
7
To install the switch box, see
To install the switch box
1
install the switch box in the correct location on the indoor unit.
a a
b
c
d
e
a
Grouding wire screw
b
Heat exchanger thermistor
c
Indoor unit PCB
d
Switch box screw
e
Switch box
2
Route the connectors of the indoor unit fan motor, swing flap motor and
swing raster motor (if equipped) inside the switch box and connect them to
the indoor unit PCB.
3
Install and tighten the screw to secure the switch box.
4
Install the heat exchanger thermistor in its holder.
5
Connect the grounding wires to the heat exchanger using the screws.
6
Connect the power supply wiring to the power supply terminal X1M.
7
Install the power supply wiring bracket. Install and tighten the screw.
To re-install the front grille
1
Install the front grille and firmly engage the 3 upper hooks.
2
Install 2 screws (class 20~35) or 3 screws (class 50~71) back on the front grille.
3
Install the air filter and then mount the front panel.
To re-install the front panel
1
Attach the front panel. Align the shafts with the slots and push them all the
way in.
2
Close the front panel, see
Содержание Comfora ARXP20L
Страница 170: ......
Страница 171: ......
Страница 172: ...ESIE18 01D 2022 02 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...