Attach insulation sleeve
Round crimp-style terminal
Electric wire
Use the correct screwdriver for terminal screws tightening. Unsuitable screwdrivers can damage the screw head.
Over tightening can damage the terminal screw.
Do not connect wire of different gauge to same terminal.
Keep wiring in an orderly manner. Prevent the wiring from obstructing other parts and the terminal box cover.
•
•
•
•
INDICATOR LIGHTS
Error Description
Cool LED
Error Indication
Room Sensor error
1 blinks
E1
Pipe Water Sensor error
2 blinks
E2
Water Pump error
3 blinks
E6
Pipe Water Temperature fault
5 blinks
E5
Operating Limits:
Thermal carrier : Water
Water temperature : 4°C ~ 10°C (Cooling)
Maximum water pressure : 16 bar
Air temperature : (as below)
Cooling Mode
Ts: Dry bulb temperature. Th: Wet bulb temperature.
OPERATING RANGE
Temperature
Ts °C/°F
Th °C/°F
Minimum indoor temperature
19.0 / 66.2
14.0 / 57.2
Maximum indoor temperature
32.0 / 89.6
23.0 / 73.4
All wires must be
fi
rmly connected.
Make sure all the wire do not touch the refrigerant pipings, compressor or any moving parts.
The connecting wire between the indoor unit and the outdoor unit must be clamped by using provided cord anchorage.
The power supply cord must be equivalent to H07RN-F which is the minimum requirement.
Make sure no external pressure is applied to the terminal connectors and wires.
Make sure all the covers are properly
fi
xed to avoid any gap.
Use round crimp-style terminal for connecting wires to the power supply terminal block. Connect the wires by matching
to the indication on terminal block. (Refer to the wiring diagram attached on the unit).
•
•
•
•
•
•
•
Connect wires of the
same gauge to both side.
Do not connect wires of the
same gauge to one side.
Do not connect wires
of different gauges.