9
|
Electrical installation
Installer reference guide
108
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
3
4
35
X2M
3
Fix the cable with cable ties to the cable tie mountings.
9.2.5 To connect the user interface
This topic describes the following:
▪
Connecting the user interface cable to the outdoor unit.
▪
Installing the user interface, and connecting the user interface cable to it.
▪
(if necessary) Opening the user interface after it is installed.
Connecting the user interface cable to the outdoor unit
Wires: 4×(0.75~1.25 mm²)
Maximum length: 200 m
[2.9]
Control
[1.6]
Room sensor offset
1
2
Connect the user interface cable to the outdoor unit. Fix the cable with cable
ties to the cable tie mountings.
X5M.11
P1P2
+
PSU
X1B
X5M.12
X5M.16
X5M.15
4
3
2
1
a
a
User interface: Required for operation. Delivered with the unit as accessory.