4/11
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
5.A
[6-08]
R/W
2~20°C, step: 1°C
10°C
5.B
R/W
0: Fixed
1: Weather dependent
└─
WD curve
5.C
[0-0B]
R/W
35~[6-0E]°C, step: 1°C
55°C
5.C
[0-0C]
R/W
45~[6-0E]°C, step: 1°C
55°C
5.C
[0-0D]
R/W
10~25°C, step: 1°C
15°C
5.C
[0-0E]
R/W
-40~5°C, step: 1°C
-10°C
Tank
5.D
[6-01]
R/W
0~10°C, step: 1°C
2°C
User settings
└─
Quiet
7.4.1
R/W
0: OFF
1: Manual
2: Automatic
└─
Electricity price
7.5.1
R/W
0,00~990/kWh
1/kWh
7.5.2
R/W
0,00~990/kWh
1/kWh
7.5.3
R/W
0,00~990/kWh
1/kWh
User settings
7.6
R/W
0,00~990/kWh
0,00~290/MBtu
1,0/kWh
Installer settings
└─
Configuration wizard
└─
System
9.1
[E-03]
R/W (*1)
R/O (*2)
0: no BUH (*1)
1: External BUH
2: 3V (*2)
9.1
[E-05]
[E-06]
[E-07]
R/W
0: No DHW
2: EKHW
7: EKHWP
9.1
[4-06]
R/W
0: Manual
1: Automatic(normal SH/DHW ON)
2: Auto red SH/DHW ON
3: Auto red SH/DHW OFF
4: SH ON/DHW OFF
9.1
[7-02]
R/W
0: Single zone
1: Dual zone
└─
Backup heater
9.1
[5-0D]
R/W (*1)
R/O (*2)
0: 230V, 1~
1: 230V, 3~
2: 400V, 3~
9.1
[4-0A]
R/W
0: 1
1: 1/1+2
2: 1/2
3: 1/2 + 1/1+2 in emergency
9.1
[6-03]
R/W
0~10kW, step: 0,2kW
0kW (*1)
3kW (*2)
9.1
[6-04]
R/O (*2)
R/W (*1)
0~10kW, step: 0,2kW
0kW
└─
Main zone
9.1
[2-0C]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.1
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
9.1
R/W
0: Fixed
1: WD heating, fixed cooling
2: Weather dependent
9.1
R/W
0: No
1: Yes
9.1
[1-00]
R/W
-40~5°C, step: 1°C
-10°C
9.1
[1-01]
R/W
10~25°C, step: 1°C
15°C
9.1
[1-02]
R/W
[9-01]~[9-00], step: 1°C
35°C
9.1
[1-03]
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
25°C
9.1
[1-06]
R/W
10~25°C, step: 1°C
20°C
9.1
[1-07]
R/W
25~43°C, step: 1°C
35°C
9.1
[1-08]
R/W
[9-03]~[9-02]°C, step: 1°C
22°C
9.1
[1-09]
R/W
[9-03]~[9-02]°C, step: 1°C
18°C
└─
Additional zone
9.1
[2-0D]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.1
R/W
0: Fixed
1: WD heating, fixed cooling
2: Weather dependent
9.1
R/W
0: No
1: Yes
9.1
[0-00]
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
25°C
9.1
[0-01]
R/W
[9-05]~[9-06]°C, step: 1°C
35°C
Hysteresis
Setpoint mode
Leaving water value for high ambient temp. for DHW WD curve.
Leaving water value for low ambient temp. for DHW WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Margin
Activation
High
Medium
Low
Gas price
BUH type
Domestic hot water
Emergency
Number of zones
Voltage
Configuration
Capacity step 1
Additional capacity step 2
Emitter type
Control
Setpoint mode
Schedule
Low ambient temp. for LWT main zone heating WD curve.
High ambient temp. for LWT main zone heating WD curve.
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
Low ambient temp. for LWT main zone cooling WD curve.
High ambient temp. for LWT main zone cooling WD curve.
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
Emitter type
Setpoint mode
Schedule
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
4P627273-1 - 2020.09
(#) Setting is not applicable for this unit.
(*1) *V3/W1
(*2) *3V3/3W1
(*3) EDLA*
(*4) EBLA*