background image

3

EN

GENERAL

1.1 

General warnings   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

EKRTCTRL1

2.1 

Assembly, set-up and connection of on-board control panels    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2.2 

Assembly  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2.3 

Set-up of auxiliary dip-switch functions B and C  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2.4 

CP presence contact input connection (only for EKRTCTRL1)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2.5 

Air temperature probe assembly (only for model EKRTCTRL1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2.6 

EKRTCTRL1 connections   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

EKWHCTRL0

3.1 

Continuous modulation circuit board for connecting remote thermostat  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

3.2 

LED Indications (Ref. A)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

3.3 

EKWHCTRL0 connections   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

EKWHCTRL1

4.1 

Wall-mounted remote control panel assembly EKWHCTRL1  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

4.2 

Spring-loaded terminal connections -AB+ and CP   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

4.3 

CP occupancy contact input connection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

4.4 

EKWHCTRL1 Connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

EKRTCTRL2

5.1 

Assembly and connections for on-board control panel EKRTCTRL2  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

5.2 

Assembly  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

5.3 

Air temperature probe assembly   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

5.4 

EKRTCTRL2 Connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

SETUP MENU FOR EKRTCTRL1 - EKWHCTRL1 - EKRTCTRL2

6.1 

Setup menu  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

EKPCBO

7.1 

Assembly and connections for on-board control panel EKPCBO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

7.2 

Assembly  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

7.3 

EKPCBO Connections   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

7.4 

Warnings table  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

VERSIONS WITH CONNECTIONS ON THE RIGH

8.1 

Motor connection in versions with hydraulic connections on the right EKREPLH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Содержание Altherma EKRTCTRL1

Страница 1: ...EKRTCTRL1 EKRTCTRL2 EKWHCTRL0 EKWHCTRL1 EKPCBO INSTALLATION MANUAL Daikin Altherma heat pump convector options ...

Страница 2: ...efers to pages containing instructions or information for the user I Installer Refers to pages containing instructions or information for the installer S Service Refers to pages containing instructions or information for the CUSTOMER TECHNICAL ASSISTANCE SERVICE installer Editorial pictograms Safety pictograms Warning The operation described may cause physical harm if not carried out in accordance...

Страница 3: ...WHCTRL1 4 1 Wall mounted remote control panel assembly EKWHCTRL1 11 4 2 Spring loaded terminal connections AB and CP 12 4 3 CP occupancy contact input connection 12 4 4 EKWHCTRL1 Connections 13 5 EKRTCTRL2 5 1 Assembly and connections for on board control panel EKRTCTRL2 14 5 2 Assembly 14 5 3 Air temperature probe assembly 15 5 4 EKRTCTRL2 Connections 15 6 SETUP MENU FOR EKRTCTRL1 EKWHCTRL1 EKRTC...

Страница 4: ...place safety regulations After unpacking check that the contents are intact and that all parts are included If not contact the agent who sold the appliance to you It is forbidden to modify the safety or adjustment devices without authorisation from and indications of the manufacturer It is forbidden to dispose of or leave in the reach of children the packaging materials which could become a source...

Страница 5: ...M using the fixing screws the minimum force that must be applied for tightening screws must be around 2N connect the fast connector of the MOTOR to the other on the board ref I on the two GRID block terminals ref L there is a bridge that allows the FWXM series to work without a microswitch For other versions remove the bridge and connect the two terminals originating on the grill safety microswitc...

Страница 6: ...to ON when cooling the fan operates at the minimum speed even after having reached the set point to allow for more uniform operation of the temperature probe and to avoid layering in the air With the cursor in the OFF position the functions are cycled 4 minutes ON 10 minutes OFF On closing the contact connected to the CP input ref A the panel is placed in stand by mode If the contact is open the u...

Страница 7: ...o position the temperature probe ref A pass the probe through the hole on the shoulder ref B insert the probe into the lower hole ref C fix the probe on the relevant hook ref D Air temperature probe assembly only for EKRTCTRL1 ...

Страница 8: ...rical power supply BO boiler consent output free contact max 1A CH chiller consent output free contact max 1A CP presence input sensor if closed the fan coil unit is placed in standby If after switching the power on the board detects the H2 probe start up occurs in normal conditions with the minimum water temperature when heating 30 C and maximum when cooling 20 C The board also has a function whe...

Страница 9: ... Green LED Indicates that the unit is operational Flashing indicates an anomaly LED off unit is off or has no power Error signals Error Display Communication error The circuit board expects continuous information exchange on the serial line with the wall mounted control EKWHCTRL1 If this exchange is lost for more than 5 minutes an error warning is displayed and the unit deactivated 6 flashes pause...

Страница 10: ...al conditions with the minimum water temperature when heating 30 C and maximum when cooling 20 C The board also has a function when there is no probe in such cases the fan stop minimum and maximum thresholds are ignored Rigid or flexible wires with a 0 2 to 1 5 mm cross section 0 75 mm if two wires are connected to the same terminal block can be inserted in the 4 spring loaded terminal blocks ref ...

Страница 11: ...and around 1 5m from the floor The wall mounted remote control is inside the pre assembled package therefore prior to affixing to the wall the two parts should be separated by unhooking the two protruding teeth on the rear A Use the base of the controller ref B in diagram to trace the fixing points on to the wall use two opposing holes Then proceed with the following operations drill holes in the ...

Страница 12: ...of pliers to insert correctly Push the wire completely in and check that it is anchored by pulling it gently To disconnect the cables press the corresponding white indent ref C with a screwdriver and remove the conductor Spring loaded terminal connections AB and CP CP occupancy contact input connection On closing the contact connected to the CP input ref A the panels are placed into stand by If th...

Страница 13: ...ions RS485 keeping the power supply cables separate Chase out the wall in order to minimise the length of the leads complete the line with the supplied 120 Ω heating element do not make star connections The RS485 cable connection is polarised respect the A and B indications on every periphery connected for connecting it is preferable to use a shielded two core cable with a minimum thickness of 0 3...

Страница 14: ...m in summer Check that they are correctly inserted into the compartment on the battery Connect the electrics tidy cables and fix them with the three clevises supplied ref G close the box with the 4 screws ref H refit the vanity plate on the side of the unit tighten the upper screws on the control panel place the screw head covers in their housing on the control panel N B For versions with hydrauli...

Страница 15: ...TCTRL2 Connections H2 water temperature probe 10 kΩ AIR air temperature probe 10 kΩ M1 DC inverter fan motor S1 grill safety micro switch Y1 water solenoid valve 230V 50Hz 1A output voltage Y2 Mobile flap connection 230V 50Hz 1A output voltage L N 230V 50Hz electrical power supply If after switching the power on the board detects the H2 probe start up occurs in normal conditions with the minimum w...

Страница 16: ...t action the control goes off and the settings is memorised Setup menu Key Operation Display press the key ON for 10 sec the device turns on and the temperature appears continue to press until Ad appears Ad Reserved 01 default uu Reserved no default Ub Adjust buzzer volume br Adjust the brightness di Digital input rZ Reserved no default rb Reserved no default Fr Factory reset ot Offset probe T oh ...

Страница 17: ...he seasonality is locked It is not possible to modify it through the key of the control For return to the default settings set the digital input to CP Display Operation CP clean contact default CO cooling open CC cooling close Settings of the digital input To reset the control to factory settings Display Operation select YS to reset the settings select no to keep the current settings Factory reset...

Страница 18: ... humidity using a reliable device Adjust the value in a range of 9 C to 9 C at variations of 1 C After 30 seconds from the last action the control goes off and the settings is memorised Display Operation the adjustment range is from 9 to 9 Sensor offset settings humidity probe To change the temperature unit Display Operation select C o F Scale ...

Страница 19: ...FWXM series to work without a microswitch For other versions remove the bridge and connect the two terminals originating on the grill safety microswitch N B should the two brown terminals on the unit be too short replace them with those included in the kit packaging make the electrical connections tidy the cabling refit the vanity plate on the side of the unit tighten the upper screws on the contr...

Страница 20: ...rvo power output 230V 50Hz 1A EKPCBO Connections Warnings table The board provides diagnostics in the event of anomalies which can be interpreted from combinations of LEDs The following table summarises the warnings Flashing LED TA contact open Flashing LED TA contact closed 4 flashing LEDs S1 contact open LED on supersilent speed active 400 rpm LED on minimum speed active 680 rpm LED on medium sp...

Страница 21: ... must stay in position the EKREPLH kit must be used as an accessory The cable with male female connectors is connected to the motor on the right and to the quick connector on the left MOTOR on the board ref D Furthermore the two terminals connected to the grill safety micro switch are extended and connected on the left hand side to contact S1 on the board ref E The cables should be passed behind t...

Страница 22: ...22 S I U ...

Страница 23: ...23 S I U EN ...

Страница 24: ...Copyright 2019 Daikin cod N420250A ...