10 Maintenance and service
Installation and operation manual
32
EHY32AA
Daikin Altherma hybrid monobloc – Gas boiler module
4P538953-1 – 2018.06
8
Pull the bottom of the pipe forwards and remove the pipe
downwards by turning the pipe alternately clockwise and
counterclockwise.
9
Lift the condensate drain pan on the left-hand side from the
connection to the condensate trap.
10
Turn it to the right with the condensate trap connection over the
edge of the base tray.
11
Push the backside of the condensate drain pan downwards
from the connection to the heat exchanger and remove it.