6
|
Application guidelines
Installer reference guide
55
ERGA04~08EA + EHBH/X04+08EF
Daikin Altherma 3 R W
4P629085-1B – 2021.11
Setup
b
c
a
d
M
e
f
a
DHW tank
b
Cold water IN
c
Hot water OUT (shower (field supply))
d
Motorised 3‑way valve (field supply)
e
DHW pump (field supply)
f
Non‑return valve (field supply)
▪
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see
"9.3.5 To connect the domestic hot water
126].
Configuration
The indoor unit can control DHW pump operation. For more information, see
137].
6.5 Setting up the energy metering
▪
Via the user interface, you can read out the following energy data:
-
Produced heat
-
Consumed energy
▪
You can read out the energy data:
-
For space heating
-
For space cooling
-
For domestic hot water production
▪
You can read out the energy data:
-
Per month
-
Per year
INFORMATION
The calculated produced heat and consumed energy are an estimation, the accuracy
cannot be guaranteed.