16
|
Technical data
Installer reference guide
280
ERGA04~08EA + EHBH/X04+08EF
Daikin Altherma 3 R W
4P629085-1B – 2021.11
16.8 ESP curve: Indoor unit
Note:
A flow error will occur when the minimum water flow rate is not reached.
0
0
5
10
15
20
25
30
35
20
30
C
40
50
60
70
10
4D112014
B (l/min)
A (kPa)
A
External static pressure in the space heating/cooling circuit
B
Water flow rate through the unit in the space heating/cooling circuit
C
Operation range
Dashed lines:
Operation area is extended to lower flow rates only in case the unit
operates with heat pump only. (Not in startup, no backup heater operation, no
defrost operation.)
Notes:
▪
Selecting a flow outside the operating area can damage the unit or cause the unit
to malfunction. See also the minimum and maximum allowed water flow range in
the technical specifications.
▪
Make sure water quality complies with EU directive 2020/2184.