SiBE12-933_A
Wiring Diagrams
Appendix
275
2.1.4 Floor Standing Type
FVXS25FV1B, FVXS35FV1B, FVXS50FV1B
→
~
~
3D055953A
CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
: PROTECTIVE EARTH
F1U
: FUSE
H1P,H2P
: PILOT LAMP
M1F
: FAN MOTOR
M1S
: SWING MOTOR
M2S
: LOWER AIR OUTLET MOTOR
PCB1~PCB4 : PRINTED CIRCUIT BOARD
R1T,R2T
: THERMISTOR
S1~S49
: CONNECTOR
S1W
: OPERATION SWITCH
S2W(4)
: UPWARD AIR FLOW LIMIT SWITCH
S4W
: AIR OUTLET SELECTION SWITCH
X1M
: TERMINAL STRIP
E3
: EARTH TERMINAL(HEAT EX.)
E4
: EARTH TERMINAL(SHIELD PLATE)
1
3
outdoor
FIELD WIRING.
2
X1M
1
3
2
BLK
WHT
RED
GRN
GRN / YLW
E3
E4
E3
GRN
M1F
M
S49
PCB1
R1T
t°
t°
R2T
RED
BLU
BRN
ORG
WHT
S48
S32
HA
S21
1
4
7
S1
E1
SA1
V2
H3
H2
H1
F1U
3.15A
V1
RECTIFIER
TRANSMISSION
CIRCUIT
PCB2
S26
S46
S27
S47
S42
1
6
1
5
S41
RED
ORG
YLW
PNK
BLU
RED
ORG
YLW
PNK
BLU
M
M1S
M
M2S
indoor
LED1
H1P
LED2
H2P
S1W
SIGNAL
RECEIVER
PCB4
PCB3
S2W(4)
S4W
WIRELESS
REMOTE
CONTROLLER