7.Electrical Interface
© 2023 China Daheng Group, Inc. Beijing Image Vision Technology Branch 93
Delay time (td): the time required from 50% rising of OUTPUT2 to the decrease to 90% of the
maximum value of LINE2
Falling time (tf): the time taken for the amplitude of LINE2 to decrease from 90% to 10% of the
maximum value
Storage time (ts): the time required from 50% falling of OUTPUT2 to the rise to 10% of the maximum
value of LINE2
Rising time (tr): the time for the response of LINE2 to rise from 10% to 90% of its final value
When Line2/3 is configured as output, the internal equivalent circuit of camera is shown below, taking
Line2 as an example
1
2
8
7
6
4
5
3
EXVCC(5-24V)
Line2
OUTPUT2
33
Ω
PTC
External circuit
Figure 7-25 Internal equivalent circuit of camera when Line2 is configured as output (MER2/ME2P/ME2L)
EXVCC (5-24V)
Line2
OUTPUT2
PTC
1
6
2
5
3
4
External circuit
Figure 7-26 Internal equivalent circuit of camera when Line2 is configured as output (ME2S)