1
The gray & red (The waveform in
secondary part of the transformer)
2
Measuring the wave form in case of the
removing condenser by the removal ripple
C33
3
It is removed the ripple with attaching the
C33(2200µF).
4
The waveform of output in the
REGULATOR I.C 7806.
5
The waveform after passing the D2.
ELECTRIC POWER SUPPLY UNIT
1) CIRCUIT DIAGRAM
2) EXPLANATION OF CIRCUIT
• The primary voltage of the transformer sets 220V, the secondary voltage of the transformer is full
wave rectified by use of the D7 (1N4003) & D8(1N4003).
33
32
16
C3 6
104Z
104Z C31
3300
µ
F
10V
470
µ
F
16V
2200
µ
F
35V
104Z
C13
C34
C32
D1,1N4003
7806
REGULATOR
D8,1N4003
C33
COMMON
220V
D7,1N4003
12V
0V
0V
5.4V
0V
6V
0V
f=60Hz
Vpeak=11.4V
Vrms=8V
12V
WATER LEVEL SENSOR UNIT
1) CIRCUIT DIAGRAM
2) EXPLANATION OF CIRCUIT
• Push the power switch. And, in order to carry on the action of course selection, input the selection of
frequency according to each water level selection.
• The frequency of water level sensor in each water level becomes square wave and is sended to the
MICOM.
If the water level is selected ‘HIGH’ in washing, water suppply proceeds until inputing the frequency 22.70
KHz of ‘HIGH’ in the MICOM terminal No. 24. Being finished the water supply, washing process is
proceeded. After the washing process, water level reaches to RESET point, and then after the (D) + 60
seconds, the spin process begins.
• The value of the frequency between the MICOM terminal No. 24 and the GND.
3) CAUTION FOR A/S
• The output of the frequency in the WATER LEVEL SENSOR varies in accordance with temperature and
using condition. If it doesn’t input the output of the WATER LEVEL SENSOR in the MICOM, the error
message is displayed as ‘E9’. In case of proceeding the water supply continuously in ‘HIGH’ water level,
it is desirable to change the WATER LEVEL SENSOR because of the defect in the WATER LEVEL
SENSOR.
• Check the TR Q4(A1270Y)
• Being checked with tester, the value of the voltage reaches about 4V.
• As the frequency is low, the water level is higher.
M
I
C
O
M
24
R18,220
Ω
Q4
A1270
R20,10K
Ω
R21,10K
Ω
R22, 3.9K
Ω
WATER LEVEL NAME
FREQUENCY
WATER LEVEL
DWF-7588
DWF-9288
DWF-1088
HIGH
22.52KHz
400±15
80L
98L
96L
MIDDLE
23.04KHz
340+10, -15
68L
78L
81L
LOW
23.56KHz
280±15
55L
61L
65L
SMALL
24.05KHz
220±15
42L
48L
49L
E.SMALL
24.33KHz
180±15
30.5L
33L
36L
RESET
25.02KHz
0
25.40KHz
60 ±20
5.4V
0V
f=22~25KHz
KHz
Содержание DWF-7588TE
Страница 29: ...53 52 PARTS DIAGRAM...
Страница 33: ...60 CIRCUIT DIAGRAM...
Страница 34: ...63 62 BARE PCB BOTTON BARE PCB TOP...