51
rum Wa
Symptoms
Detailed Symptoms
Cause
Diagnosis
Solution
PCB Error
Mode
#$!
Water Level Sensor
1) Spec. of Water Level Sensor
2) Breakdown Analysis
O/F: Forced drainage is
necessary as water
level is high. When
this level is reached,
water supply must be
stopped and drainage
must be forcefully
administered.
RESET :
1. Spin-drying begins
30sec after drainage
level reset is reached.
2. Heater operation level
Low: Small load of laundry, therefore considered to be
water level of 'low'
Medium: Large load of laundry
Medium High: Water level for rinsing
Safety: Door open possible
Door opened only when water level is below
safety level
Model
Code
Classification
O/F
Medium High Medium
Low
Safety
Reset
Initial(Defect) Inlet Angle
3614825220
Frequency 22.60
3
23.10
3
23.20
3
24.00
3
24.40
3
24.70
3
25.80
3
90
4
WD1132
DN-DD03,
Water level
260
5
15
225
5
15
220
5
7
170
5
15
140
5
15
120
5
20
0
DL-DW03
(mm)
Continuous
water
supply
"E9"
Water valve normal
Occurrence in water level
sensor
30kHz or higher
Defect in pressure sensor
hose
Blocking of pressure sensor
hose
Connector loosened
Wiring short
Check for holes.
Visual checking
Visually check connector
connection status.
Wiring short ->
conduction test
Replace hose.
Remove foreign substances.
Administer re-insertion.
"E2"
"E2"
"E9"
"E9"
Содержание DWD-WD135 SERIES
Страница 48: ...47 PCB PIN ARRANGEMENT ...
Страница 60: ...59 BLDC Motor Power Transmission System of BLDC Motor ...
Страница 65: ...64 Wiring Diagram ...
Страница 71: ...70 PLATE TOP ASS Y 1 Remove 3 screws 2 Remove 4 screws ...
Страница 73: ...72 VALVE 3WAY 1 Remove 4 screws 2 Separate 3 connectors 3 Separate 3 hose clamps ...
Страница 74: ...73 MAIN PCB ASS Y 1 Separate harness and separate PCB cover 2 Separate connector 3 Remove 1 screw ...