6-4. LE (Lock Error) - Door opening error
1) Conditions of Occurrence
%
When intending to begin cycle by pressing start/ temporary stop button while door is opened
2) All LEDs are turned off and 'LE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
6-5. E1 - Water level detection error
1) Conditions of Occurrence
%
In case water level is below reset or overflow is detected in line test mode
2) Water supply motor is kept on until water level falls below reset.
3) All LEDs are turned off and 'E1' blinks in 18:88 display.
4) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
5) Error display is cleared when turning off/ on power.
6-6. E2 - Overflow error
1) Conditions of Occurrence
%
In case water level in water tank is above overflow level due to continuous operation of water supply
valve
2) Water supply motor is kept on until water level falls below reset.
3) All LEDs are turned off and 'E2' blinks in 18:88 display.
4) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
5) Error display is cleared when turning off/ on power.
Содержание DWD-WD135 SERIES
Страница 48: ...47 PCB PIN ARRANGEMENT ...
Страница 60: ...59 BLDC Motor Power Transmission System of BLDC Motor ...
Страница 65: ...64 Wiring Diagram ...
Страница 71: ...70 PLATE TOP ASS Y 1 Remove 3 screws 2 Remove 4 screws ...
Страница 73: ...72 VALVE 3WAY 1 Remove 4 screws 2 Separate 3 connectors 3 Separate 3 hose clamps ...
Страница 74: ...73 MAIN PCB ASS Y 1 Separate harness and separate PCB cover 2 Separate connector 3 Remove 1 screw ...