![Daewoo DWD-UD123X Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/daewoo/dwd-ud123x/dwd-ud123x_service-manual_499185048.webp)
46
3) H5 Error - Water temperature error in wool/ delicate course
①
In case water temperature in wool/ delicate course is 45
℃
or higher
②
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③
Error display is cleared when turning off/ on power.
4) H6 Error - Abnormality in washing heater
①
Within 15 minutes after heater operation begins;
In case standard temperature is of 42
℃
or lower: If temperature does not increase by 2
℃
or more In
case standard temperature is higher than 42
℃
: If temperature does not increase by1
℃
or more
②
If temperature falls below standard temperature by 2
℃
or more due to re-supply of water, etc.,
standard temperature is reset as the current temperature and error check time of15 minutes is reset.
③
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
④
Error display is cleared when turning off/ on power.
5) H8 Error - Washing heater overheating
①
In case washing heater temperature increases by 5
℃
or more within 30 seconds when there is no
water in tank, etc.
②
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
③
Error display is cleared when turning off/ on power.
Содержание DWD-UD123X
Страница 10: ...4 Parts list by ass y 8 1 PANEL F AS 1 U129 S series ...
Страница 12: ...10 1 PANEL F AS 2 U127 S series ...
Страница 16: ...14 3 CABINET F ASSY C11 C10 C07 C12 C03 C06 C09 C08 C05 C04 C01 C16 C02 C13 C14 C15 ...
Страница 18: ...16 4 CABINET ASSY ...
Страница 20: ...18 5 BASE U AS ...
Страница 22: ...20 6 TUB ASSY ...
Страница 24: ...22 7 DUCT B AS DUCT PIPE AS ...
Страница 69: ...67 1 Structure of BLDC Motor 7 HEATER BLDC MOTOR 2 Power Transmission System of BLDC Motor ...
Страница 71: ...69 8 WIRINGDIAGRAM ...