![Daewoo DWD-UD123X Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/daewoo/dwd-ud123x/dwd-ud123x_service-manual_499185045.webp)
43
6-4. LE (Lock Error) - Door opening error
1) Conditions of Occurrence
①
When intending to begin cycle by pressing start/ temporary stop button while door is opened
2) All LEDs are turned off and 'LE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
6-5. E1 - Water level detection error
1) Conditions of Occurrence
①
In case water level is below reset or overflow is detected in line test mode
2) Water supply motor is kept on until water level falls below reset.
3) All LEDs are turned off and 'E1' blinks in 18:88 display.
4) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
5) Error display is cleared when turning off/ on power.
6-6. E2 - Overflow error
1) Conditions of Occurrence
①
In case water level in water tank is above overflow level due to continuous operation of water supply
valve
2) Water supply motor is kept on until water level falls below reset.
3) All LEDs are turned off and 'E2' blinks in 18:88 display.
4) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
5) Error display is cleared when turning off/ on power.
Содержание DWD-UD123X
Страница 10: ...4 Parts list by ass y 8 1 PANEL F AS 1 U129 S series ...
Страница 12: ...10 1 PANEL F AS 2 U127 S series ...
Страница 16: ...14 3 CABINET F ASSY C11 C10 C07 C12 C03 C06 C09 C08 C05 C04 C01 C16 C02 C13 C14 C15 ...
Страница 18: ...16 4 CABINET ASSY ...
Страница 20: ...18 5 BASE U AS ...
Страница 22: ...20 6 TUB ASSY ...
Страница 24: ...22 7 DUCT B AS DUCT PIPE AS ...
Страница 69: ...67 1 Structure of BLDC Motor 7 HEATER BLDC MOTOR 2 Power Transmission System of BLDC Motor ...
Страница 71: ...69 8 WIRINGDIAGRAM ...