26
Connecting relay
specifications
Please see the below table for alarm output requirements.
Specifications
Output Ch. *
4ch relay output
Output type
Dry Contact
Connection
method
Connect the trimmed wire to terminal block
Performance
DC
24V / 1A
AC
125V / 0.5A
* Varies between different models
Connecting relay
Please refer to the below picture in regards to connecting R1~R4 output. Below picture is an example of
connecting a light bar. Please see “wire end handling” in regards to connecting/removing wires.
Connecting COM1 serial port with external devices
Connecting Text input device (ATM / POS / Access Control)
Using COM1/RS232, TEXT DATA can be recorded with synchronizing POS/ATM.
As shown in the picture, for a set up to connect COM1/RS232 (D-Sub 9pin), set up serial & text info under
“device” menu.
Connecting COM2/COM3 serial port external device
Connecting serial communication terminal for PTZ device & Keyboard device