Introduction to the Dado Door Master Controller

The Dado Door sliding door automation system is a sophisticated software and 
hardware solution for automating sliding doors.  Contrasting the typical industrial 
automations system, the Dado Door system is designed for high end residential 
applications which demand quiets, smooth, elegant, reliable operation.  Significant 
effort has gone into engineering the track automation to produce an extremely 
reliable and efficient product that requires basically no maintenance.  In the 
majority of installs, once calibrated, the system rarely if ever needs further attention. 

There are two aspects of the Dado Door automation system.  The first part of the 
install is the hardware installation.  The second part is programming the door to fit 
the application.  This manual covers the programming aspect of the installation, 
and assumes that a door has been attached to the track and is ready to be 
calibrated.   Each phase requires attention to detail to insure a positive install 
experience in addition to a positive homeowner enjoyment after installation.  

The Master Controller contains a simple and easy to follow menu directory of 
settings.    When changing a setting, they are stored permanently.  This manual will 
cover all aspects of the menu.  It is advised that the installer do not make any 
changes to a setting without first reviewing the manual.

It is advised that the Master Controller be installed in a manner so that it is easy to 
get access to if future adjustments are required.  Do not install in a room(ie attic or 
basement) such that there may be significant temperature fluctuations, moisture, or 
excessive dust accumulation.  It is ideal to have a line of sight from the Master 
Controller to the door when possible for easy programming.  During the install and 
calibration, it is best to plan for easy access to the motor and Master Controller, as 
the most frequent problems experienced by installers are due to wiring and 
connection problems.  When the motor and Master Controller are easily accessible, 
troubleshooting wiring problems is a quick and easy process.

Although much effort has gone into methods to make the door system as safe as 
possible, the is always some potential risk that the Dado Door automation system 
may cause bodily harm to persons or pets that are in the door's path.  Use a 
common sense approach as to where and how this system is installed.  

1

Содержание Door Master Controller

Страница 1: ...Manual Copyright 2013 All rights reserved No unauthorized duplication distribution or online posting without prior written consent from Dado Door LLC Dado Door LLC and the Dado Logo are registered tr...

Страница 2: ...Motor Driver Fault Error Troubleshooting 20 Advanced Motor Driver Fault Error Troubleshooting Cont d 21 Initial Calibration and Setup 22 Initial Calibration and Setup cont d 23 Error Messages 24 Error...

Страница 3: ...roller contains a simple and easy to follow menu directory of settings When changing a setting they are stored permanently This manual will cover all aspects of the menu It is advised that the install...

Страница 4: ...E fully open quickly turn off the power If the door begins the homing process towards the CLOSED position then the belt has been installed in reverse It is advised that when powering the system up for...

Страница 5: ...formation needed to set up the parameters Buttons Explained Move up or down the Main Menu Add or subtract from a number or select Yes No fields CURSOR Cycle the cursor through a menu item with more th...

Страница 6: ...gs Factory settings Do not change 4 BYPASS MODE If required at power ON the user can immediately PRESS and HOLD down the Setup Mode Button until the Main Menu appears this will bypass the diagnositcs...

Страница 7: ...erial communication Port 8 RS485 interface duplicate for daisy chain Motor 3 Phase Power Leads Connection to the Brushless DC motor power using 26VDC is made with a 3 condutor 18G specially prepared c...

Страница 8: ...y the port that will be used as a Locking Touch Screen inside the room Port A it typically the outside Touch Screen Auto Home Upon each power up the system automatically moves towards a Home switch wh...

Страница 9: ...configured to receive input from any low voltage source for remote control such as a fire alarm contact closure PiNG Proximity Sensor Option The Ping Sensor is a small device offered by Dado Door that...

Страница 10: ...system against overload due to an obstruction during the Homing phase The parameters may need to be adjusted to account for the weight speed and friction of each door by the user at the time of insta...

Страница 11: ...ng thus a higher Trip Level will be required to avoid false trips Each time the speed is adjusted in the menu the Trip Levels will need to be adjusted as well for optimal retraction If you have set th...

Страница 12: ...where the motor door are in a highly precision manner The Set Close Position value shown in the display will equate to approximately 1 500 As an example if the value says 5000 then calculate 5000 500...

Страница 13: ...ressure on the door during the closing motion Above a certain pressure on the door the door will auto retract Closing Trip Level In some cases during the last couple of inches of travel closing as the...

Страница 14: ...mber means the factor will be larger and will take longer to slow the door to a stop To cause the door to take longer to accelerate to full speed choose a higher accel factor Shorter values produce a...

Страница 15: ...opposite direction while the arrows are pressed Due to the fact that there are numerous ways a system can be set up these arrows may not always reflect the direction that the door is actually moving i...

Страница 16: ...ned on the offset value is used for the fully open position The value in the menu is approximately 1 500 So for example to create a 1 2 offset put the offset value at 250 The door should move as the s...

Страница 17: ...controller The Destination number will always be 0 by default System Input Configuration The system controller has a number of options for controlling the door On the top of the enclosure are the con...

Страница 18: ...attached to the motor that allows the system to know very precisely where the motor and door are at all times If the encoder has been damaged or the cable that connects the system controller to the m...

Страница 19: ...Fault LED on the motor driver board is lit right away then there is a problem 1 The Motor Logic cable is not plugged in from the Master Controller to the motor 2 On the motor there is a set of five w...

Страница 20: ...any wires out of a pair Each end of the CAT5 cable should be identical colors not mirrored colors When the connection problem is resolved on power up the motor driver board will only have the Green PW...

Отзывы: