Preparation and Setup

Meeting Installation Requirements

 WARNING

Observe all governing codes and ordinances during 

planning and installation. Contact your local building 

department for further information. Use only ductwork 

deemed acceptable by state, municipal and local codes.

 WARNING

To reduce the risk of personal injury caused by reaching 

over a hot appliance, cabinet storage space located 

directly above the range should be avoided.

 IMPORTANT

See the diagram for minimum installed distance from 

the hood to the cooktop surface. The minimum specified 

distance may be higher for the particular range or 

cooktop in use. Check the manufacturers specifications 

for the cooktop or range.

•  The hood canopy must be as wide as the cooktop sur-

face or wider.

•  Plan the installation so that all minimum dimensions 

are met or exceeded. 

•  Dimensions given are minimum clearances, unless oth-

erwise noted.

•  All contact surfaces between the RNIVS and any cabi-

netry or walls must be sturdy, solid, and at right angles.

•  Install the RNIVS and cooking appliance(s) so that they 

can be removed if service is required.

•  Local building codes may require the use of makeup air 

systems with ventilation systems that move air greater 

than the specified movement rate (CFM). The specified 

rate varies based on locale. Consult a qualified HVAC 

specialist when designing the system for the require-

ments in your area and to assure optimal performance.

•  An RNIVS installed inside a custom hood canopy made 

of 

combustible

 materials must be a minimum of 36” 

(91.4 cm) above the countertop cooking surface.

•  An RNIVS installed inside a custom hood canopy made 

of 

non-combustible

 materials must be a minimum of 30” 

(76.2 cm) above the countertop cooking surface.

•  An RNIVS installed inside any custom hood canopy 

using a Dacor RNIHL Series Stainless Steel Hood 

Liner must be a minimum of 30” (76.2 cm) above the 

countertop cooking surface.

E

F *

(hood/canopy materials

* From cooking surface 

E

determine distance)

Minimum Width of E: 

Upper Cabinet Cutout & Appliance Width

Models

E

RNIVS1, RNIVSR1

30 inches (76.2 cm)

RNIVS2, RNIVSR2

36 inches (91.5 cm)

Cabinet Layout Dimensions

Minimum Height of F: 

From Cooking Surface to Bottom of Hood

Materials

F

Combustible Materials (wood)

36 inches (91.5 cm)

Non-Combustible (tile, metal)

30 inches (76.2 cm)

Dacor RNIHL Hood Liners

30 inches (76.2 cm)

Metal Hood Liners

see mfg. specs

All tolerances are +1/16”, -0” (+.16, -0 cm) 

Содержание Renaissance RNIVS2

Страница 1: ...tems Models RNIVS1 RNIVS2 RNIVSR1 and RNIVSR2 Part No 109408 Rev A APPROVED FOR USE WITH ALL DACOR RANGES AND COOKTOPS TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI UL 507 STANDARD FOR ELECTRIC...

Страница 2: ...lation process Leave these installation instructions with the user Write the data plate information in the Use and Care manual before installing the unit User Keep these Installation Instructions for...

Страница 3: ...nd conditions that you don t under stand Important Safety Instructions Safety Symbols and Labels These alerts are meant to bring attention to important areas in the manual Whenever you see these symbo...

Страница 4: ...lity of explosion or fire do not store or use combustible flammable or explosive vapors and liquids such as gasoline inside or in the vicinity of this or any other appliance Also keep items that could...

Страница 5: ...device such as a tag to the electrical panel Read the Use and Care Manual completely before using the appliance Clean the appliance only as instructed in the Use and Care Manual Use only the cleaners...

Страница 6: ...nches static pressure Product Specifications General Specifications Individual Models Dacor s Renaissance Integrated Ventilation System RNIVS is designed to be installed inside custom hood canopies Co...

Страница 7: ...1 2 19 5 8 20 1 4 21 7 16 22 5 cm 46 92 cm 49 82 cm 54 43 cm 54 45 cm All tolerances are 1 16 0 0 16 0 cm RNIVS1 RNIVSR1 Dimensions RNIVS1 RNIVSR1 ISO View Top View 1 0 cm 3 8 Rear Flange Extension 3...

Страница 8: ...3 8 1 0 cm 3 8 Rear Flange Extension 3 8 3 8 1 0 cm channel depth channel height flange extension length flange Rear Flange and Channel Dimensions Side View 1 0 cm Channel Dimensions 3 8 back panel ch...

Страница 9: ...79 83 cm RNIVS2 RNIVSR2 Dimensions C L 6 3 16 15 72 cm 5 3 4 14 54 cm 6 15 24 cm 6 15 24 cm Top Centerline Dimensions Product Specifications Product Dimensions All tolerances are 1 16 0 0 16 0 cm RNI...

Страница 10: ...8 back panel 5 04 cm channel depth channel height 1 0 cm Channel Dimensions Detail 40 flange 3 8 1 0 cm 3 8 Rear Flange Extension Side View 3 8 3 8 1 0 cm channel depth channel height flange extensio...

Страница 11: ...hese tools and hardware are within reach before beginning the installation pictures vary by model Features RNIVS1 RNIVS2 Filters 2 3 LED Lights 2 2 RNIVS Grease channel 1 Baffle filter and hardware 2...

Страница 12: ...d Local building codes may require the use of makeup air systems with ventilation systems that move air greater than the specified movement rate CFM The specified rate varies based on locale Consult a...

Страница 13: ...a grounding conductor installed by a licensed electrician Do not ground the appliance or appliance wiring to a gas pipeline or to the neutral white power supply wire Do not install a fuse in the neutr...

Страница 14: ...prevent combustion by products smoke or odors from entering the home and to improve efficiency tape all duct joints securely Range hoods may interrupt the proper flow of smoke and combustion gases fr...

Страница 15: ...c coating and confirm that the inside lip is beveled If this is true proceed If not flip the frame 2 Align the screw lock washer and knob with the filter Make sure the knob is on the ridge and the scr...

Страница 16: ...y install your custom hood ventilation system Follow all electrical requirements specified in the RNIVS Installation Instructions The Renaissance RNIHL Series Hood Liner has no electrical parts Plan t...

Страница 17: ...ip around the transition kit by bending the bottom edges backward at right angles to create a 3 4 flange around the base Attaching the ATD10 1 Center the ATD10 transition kit over the duct collars 2 D...

Страница 18: ...rline dimensions overhead 4 Cut a hole that is 1 inch larger than the duct size you are using Dual exhaust models require two 2 holes Marking the Centerlines Installation Instructions Marking the Top...

Страница 19: ...NIVS be careful not to scratch or damage the unit 1 Remove the plastic film from the RNIVS 2 Install a 3 8 spacer on the back of the RNIVS or install a spacer on the canopy or wall Refer to the figure...

Страница 20: ...wall or canopy See images below that illustrate the 3 8 flange exten sion that prevents the unit from being flush against a wall The image Channel Dimensions is for added information only These dimens...

Страница 21: ...orrect gauge and capable of handling the total connected loads and meeting all codes Hardwiring the Hood Control Panel Wire Diagram L1 N1 Gnd GREEN WHITE BLACK GREEN WHITE BLACK Not used wires connect...

Страница 22: ...n External Cold Water Pipe GREEN GREEN WHITE WHITE BLACK BLACK UL CSA approved NEMA strain relief Fasten clamp tightly on metal pipe Separate No 10 minimum copper ground wire To house circuit breaker...

Страница 23: ...up to the lens of a dimmable light bulb Both are supplied parts Make sure the bulbs are clean and dry so the suction cup will stick 3 Screw it into place and remove the suction cup 4 Repeat for the re...

Страница 24: ...fan s off If the RNIVS Fails to Function Correctly 1 Verify that power is supplied to the RNIVS via the out let circuit breaker or another main power source 2 Make sure the electrical supply has not b...

Страница 25: ...ng to the instructions on pages 18 Is the ductwork completely installed Are all joints attached with sheet metal screws and wrapped with foil tape See page 13 Is the RNIVS wired and grounded according...

Страница 26: ...REMOTE BLOWER P N ILHSF 8 10 OR REMP 3 16 FAN FAN LIGHT LIGHT G W B G W B HOOD LIGHT 75W HOOD LIGHT 75W CONNECT TO 120V 60Hz 15A POWER SUPPLY WIRING DIAGRAM RNIVS1 RNIVSR1 DISCONNECT POWER SUPPLY AT T...

Страница 27: ...DISCONNECT POWER SUPPLY AT THE FUSE BOX BEFORE SERVICING THIS EQUIPMENT WIRING DIAGRAM RNIVS2 RNIVSR2 CONNECT TO 120V 60Hz 15A POWER SUPPLY HOOD LIGHT 75W HOOD LIGHT 75W B W G B W G LIGHT LIGHT FAN FA...

Страница 28: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: