background image

4

•  Do not install or operate this RNIVS if it has been damaged, dropped, has damaged electrical wires or is not work-

ing properly. If the product is damaged when received, immediately contact the dealer or builder.

•  This RNIVS must be installed and grounded by a qualified installer according to these installation instructions. 
•  Install or locate this appliance only in accordance with these installation instructions and the requirements specified 

by the manufacturer of the cooktop or range. Improper installation, adjustment, alteration, service, or maintenance 

can cause serious personal injury or property damage.

•  The user should not install, repair, or replace any part of the unit unless specifically recommended in the literature 

accompanying it. A qualified service technician should perform all other service. Contact the nearest Dacor autho-

rized service representative at (800) 793-0093, or at www.dacor.com for examination, repair or adjustment.

•  Keep all packaging materials away from children. Plastic bags can cause suffocation.
•  Do not use an extension cord or adapter plug with this appliance.
•  The installer must show the user the fuse box or circuit breaker panel box and how to turn the power on/off.
•  Before installing or servicing the RNIVS, switch the power OFF at the fuse box circuit breaker and lock the electri-

cal panel door to prevent power from being switched on accidentally. When the electrical panel cannot be locked, 

securely fasten a prominent warning device, such as a tag, to the electrical panel.

•  Read the Use and Care Manual completely before using the appliance. Clean the appliance only as instructed in the 

Use and Care Manual. Use only the cleaners specified.

•  Do not tamper with the controls.
•  Never allow the filters to become blocked or clogged. Do not allow foreign objects, such as cigarettes or napkins, to 

be sucked into the hood.

•  Clean the filters, channels, and all grease-laden surfaces often to prevent grease fires and to maintain performance.
•  If the cooktop and range hood are near a window, use an appropriate window treatment; Avoid long drapes or win-

dow coverings that could blow over the cooktop and hood and create a fire hazard.

•  Always run the fan(s) whenever the cooktop is operating.
•  Never leave the range or cooktop unattended when a burner (or element) is in use. Boil-overs and greasy spills may 

smoke and/or ignite.

•  Do not leave children alone or unattended in the area where the cooktop and range hood are in use. Never allow  

children to sit or stand on an appliance. Do not let children play with a range, cooktop, or range hood. Do not store 

items of interest to children above or around the cooktop, range, or range hood.

•  The minimum distance between the cooktop surface and the exterior part of the non-combustible hood must be at 

least 30” (76.2 cm). 

•  TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
•  PROLONGED POWER FAILURE Do not attempt to use this appliance during a continuous power failure.

Important Safety Instructions

General Safety Precautions

To reduce the risk of fire, electric shock, serious injury or death when using your appliance, follow basic safety 

precautions, including the following:

Содержание Renaissance RNIVS2

Страница 1: ...tems Models RNIVS1 RNIVS2 RNIVSR1 and RNIVSR2 Part No 109408 Rev A APPROVED FOR USE WITH ALL DACOR RANGES AND COOKTOPS TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI UL 507 STANDARD FOR ELECTRIC...

Страница 2: ...lation process Leave these installation instructions with the user Write the data plate information in the Use and Care manual before installing the unit User Keep these Installation Instructions for...

Страница 3: ...nd conditions that you don t under stand Important Safety Instructions Safety Symbols and Labels These alerts are meant to bring attention to important areas in the manual Whenever you see these symbo...

Страница 4: ...lity of explosion or fire do not store or use combustible flammable or explosive vapors and liquids such as gasoline inside or in the vicinity of this or any other appliance Also keep items that could...

Страница 5: ...device such as a tag to the electrical panel Read the Use and Care Manual completely before using the appliance Clean the appliance only as instructed in the Use and Care Manual Use only the cleaners...

Страница 6: ...nches static pressure Product Specifications General Specifications Individual Models Dacor s Renaissance Integrated Ventilation System RNIVS is designed to be installed inside custom hood canopies Co...

Страница 7: ...1 2 19 5 8 20 1 4 21 7 16 22 5 cm 46 92 cm 49 82 cm 54 43 cm 54 45 cm All tolerances are 1 16 0 0 16 0 cm RNIVS1 RNIVSR1 Dimensions RNIVS1 RNIVSR1 ISO View Top View 1 0 cm 3 8 Rear Flange Extension 3...

Страница 8: ...3 8 1 0 cm 3 8 Rear Flange Extension 3 8 3 8 1 0 cm channel depth channel height flange extension length flange Rear Flange and Channel Dimensions Side View 1 0 cm Channel Dimensions 3 8 back panel ch...

Страница 9: ...79 83 cm RNIVS2 RNIVSR2 Dimensions C L 6 3 16 15 72 cm 5 3 4 14 54 cm 6 15 24 cm 6 15 24 cm Top Centerline Dimensions Product Specifications Product Dimensions All tolerances are 1 16 0 0 16 0 cm RNI...

Страница 10: ...8 back panel 5 04 cm channel depth channel height 1 0 cm Channel Dimensions Detail 40 flange 3 8 1 0 cm 3 8 Rear Flange Extension Side View 3 8 3 8 1 0 cm channel depth channel height flange extensio...

Страница 11: ...hese tools and hardware are within reach before beginning the installation pictures vary by model Features RNIVS1 RNIVS2 Filters 2 3 LED Lights 2 2 RNIVS Grease channel 1 Baffle filter and hardware 2...

Страница 12: ...d Local building codes may require the use of makeup air systems with ventilation systems that move air greater than the specified movement rate CFM The specified rate varies based on locale Consult a...

Страница 13: ...a grounding conductor installed by a licensed electrician Do not ground the appliance or appliance wiring to a gas pipeline or to the neutral white power supply wire Do not install a fuse in the neutr...

Страница 14: ...prevent combustion by products smoke or odors from entering the home and to improve efficiency tape all duct joints securely Range hoods may interrupt the proper flow of smoke and combustion gases fr...

Страница 15: ...c coating and confirm that the inside lip is beveled If this is true proceed If not flip the frame 2 Align the screw lock washer and knob with the filter Make sure the knob is on the ridge and the scr...

Страница 16: ...y install your custom hood ventilation system Follow all electrical requirements specified in the RNIVS Installation Instructions The Renaissance RNIHL Series Hood Liner has no electrical parts Plan t...

Страница 17: ...ip around the transition kit by bending the bottom edges backward at right angles to create a 3 4 flange around the base Attaching the ATD10 1 Center the ATD10 transition kit over the duct collars 2 D...

Страница 18: ...rline dimensions overhead 4 Cut a hole that is 1 inch larger than the duct size you are using Dual exhaust models require two 2 holes Marking the Centerlines Installation Instructions Marking the Top...

Страница 19: ...NIVS be careful not to scratch or damage the unit 1 Remove the plastic film from the RNIVS 2 Install a 3 8 spacer on the back of the RNIVS or install a spacer on the canopy or wall Refer to the figure...

Страница 20: ...wall or canopy See images below that illustrate the 3 8 flange exten sion that prevents the unit from being flush against a wall The image Channel Dimensions is for added information only These dimens...

Страница 21: ...orrect gauge and capable of handling the total connected loads and meeting all codes Hardwiring the Hood Control Panel Wire Diagram L1 N1 Gnd GREEN WHITE BLACK GREEN WHITE BLACK Not used wires connect...

Страница 22: ...n External Cold Water Pipe GREEN GREEN WHITE WHITE BLACK BLACK UL CSA approved NEMA strain relief Fasten clamp tightly on metal pipe Separate No 10 minimum copper ground wire To house circuit breaker...

Страница 23: ...up to the lens of a dimmable light bulb Both are supplied parts Make sure the bulbs are clean and dry so the suction cup will stick 3 Screw it into place and remove the suction cup 4 Repeat for the re...

Страница 24: ...fan s off If the RNIVS Fails to Function Correctly 1 Verify that power is supplied to the RNIVS via the out let circuit breaker or another main power source 2 Make sure the electrical supply has not b...

Страница 25: ...ng to the instructions on pages 18 Is the ductwork completely installed Are all joints attached with sheet metal screws and wrapped with foil tape See page 13 Is the RNIVS wired and grounded according...

Страница 26: ...REMOTE BLOWER P N ILHSF 8 10 OR REMP 3 16 FAN FAN LIGHT LIGHT G W B G W B HOOD LIGHT 75W HOOD LIGHT 75W CONNECT TO 120V 60Hz 15A POWER SUPPLY WIRING DIAGRAM RNIVS1 RNIVSR1 DISCONNECT POWER SUPPLY AT T...

Страница 27: ...DISCONNECT POWER SUPPLY AT THE FUSE BOX BEFORE SERVICING THIS EQUIPMENT WIRING DIAGRAM RNIVS2 RNIVSR2 CONNECT TO 120V 60Hz 15A POWER SUPPLY HOOD LIGHT 75W HOOD LIGHT 75W B W G B W G LIGHT LIGHT FAN FA...

Страница 28: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...

Отзывы: