Installation requirements
English
20
Installation requirements
Cutout dimensions of countertop
Vertical
combustible
surface
E
G
H
H
F
Rear wall
Minimum distance to combustible side
wall above countertop (both sides)
Model
(E) Min.
(F) Min.
(G) Min.
(H) Min.
DTG30M954F* with no
downdraft
2⅞”
(7.2 cm)
19¾”
(50.1 cm)
28
11
/
16
”
(72.7 cm)
12”
(30.4 cm)
DTG30M954F* with ERV30 or
PRV30
⅜”
(0.9 cm)
22½”
(57.1 cm)
7½”
(19.0 cm)
DTG30M954F* with RV30
⅝"
(1.5 cm)
22¼”
(56.4 cm)
DTG36M955F* with no
downdraft
2⅞”
(7.2 cm)
19¾”
(50.1 cm)
34
11
/
16
”
(87.9 cm)
12”
(30.4 cm)
DTG36M955F* with ERV3615 or
PRV36
⅜”
(0.9 cm)
22½”
(57.1 cm)
7½”
(19.0 cm)
DTG36M955F* with RV36
⅝"
(1.5 cm)
22¼”
(56.4 cm)
CAUTION
Cut out dimension should be observed for installation. Enlargement in cut out dimension
may cause hazard.
Install_NA9300K_MOD_DTG30M954FS_DG68-00926A-01_EN+MES+CFR.indb 20
6/19/2018 6:49:16 PM
Содержание DTG30M954F
Страница 45: ...MEMO Install_NA9300K_MOD_DTG30M954FS_DG68 00926A 01_EN MES CFR indb 45 6 19 2018 6 49 22 PM ...
Страница 46: ...MEMO Install_NA9300K_MOD_DTG30M954FS_DG68 00926A 01_EN MES CFR indb 46 6 19 2018 6 49 22 PM ...
Страница 93: ...NOTAS Install_NA9300K_MOD_DTG30M954FS_DG68 00926A 01_EN MES CFR indb 45 6 19 2018 6 49 36 PM ...
Страница 94: ...NOTAS Install_NA9300K_MOD_DTG30M954FS_DG68 00926A 01_EN MES CFR indb 46 6 19 2018 6 49 36 PM ...
Страница 141: ...MÉMO Install_NA9300K_MOD_DTG30M954FS_DG68 00926A 01_EN MES CFR indb 45 6 19 2018 6 49 49 PM ...
Страница 142: ...MÉMO Install_NA9300K_MOD_DTG30M954FS_DG68 00926A 01_EN MES CFR indb 46 6 19 2018 6 49 49 PM ...