manualshive.com logo in svg
background image

GAS COOKTOP INSTALLATION INSTRUCTIONS

WARNING

 If the information in this manual is not followed 

exactly, a fire or explosion may result causing property damage, 

personal injury or death.

FOR YOUR SAFETY:

—  Do not store or use gasoline or other flammable vapors and 

liquids in the vicinity of this or any other appliance.

—  WHAT TO DO IF YOU SMELL GAS:

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any phone in your 

building.

•  Immediately call your gas supplier from a neighbor's phone.

  Follow the gas supplier's instructions.

•  If you cannot reach your gas supplier, call the fire department.

—  Installation and service must be performed by a qualified 

installer, service agency or the gas supplier.

 

 

318205454 (1302) Rev. B

 

English - pages 1-9

Wiring Diagram 10

All dimensions are stated in inches and (cm).

Dimension 

H

 includes a 5" (12.7 cm) space underneath the cooktop for connection to gas 

supply line.

NOTE: Wiring diagrams for this cooktop are enclosed in this booklet

Printed in Canada

Appliances Installed 

in the state of 

Massachusetts:

This Appliance can only 

be installed in the state 

of Massachusetts by a 

Massachusetts licensed 

plumber or gas fitter. 

This appliance must be 

installed with a three (3) 

foot / 36 in. long flexible 

gas connector. A "T" 

handle type manual gas 

valve must be installed 

in the gas supply line to 

this appliance.

PRODUCT DIMENSIONS

MODEL

A. WIDTh

B. DEpTh

C. hEIghT

D. BOx WIDTh

E. BOx DEpTh

30" G

as Cooktop

30 (76.2)

21 ¾ (55.2)

4 ¼ (10.8)

27 (68.6)

19 (48.3)

CUTOUT DIMENSIONS

F. WIDTh

g. DEpTh

h. hEIghT BElOW 

COOKTOP

MODEL

MINIMUM

mAxImum

MINIMUM

mAxImum

30" G

as Cooktop

27 ¼ (69.2)

28 ½ (72.4)

19 

1

/

8

 (48.6)

19 ¾ (50.2)

8 (20.3)

H

A

B

E

30” Min. *
(76.2 cm)

F

D

C

G

Figure 1

gas Cooktop 

Cutout 

Dimensions

gas Cooktop 

Dimensions

INSTAllATION AND SERVICE muST BE pERFORmED BY A 

QuAlIFIED INSTAllER.

ImpORTANT: SAVE FOR lOCAl ElECTRICAl INSpECTOR'S uSE.

READ AND SAVE ThESE INSTRuCTIONS FOR FuTuRE REFERENCE.

Содержание 318205454 (1302)

Страница 1: ...cm space underneath the cooktop for connection to gas supply line NOTE Wiring diagrams for this cooktop are enclosed in this booklet Printed in Canada Appliances Installed in the state of Massachusetts This Appliance can only be installed in the state of Massachusetts by a Massachusetts licensed plumber or gas fitter This appliance must be installed with a three 3 foot 36 in long flexible gas conn...

Страница 2: ...read it carefully Air curtain or other overhead hoods which operate by blowing a downward air flow on to a range shall not be used in conjunction with gas ranges other than when the hood and range have been designed tested and listen by an independent test laboratory for use in combination with each other Be sure your cooktop is installed and grounded properly by a qualified installer or service t...

Страница 3: ... Cutout and Nearest Combustible Surface Above Countertop Clearance 30 76 2 cm Min Clearance Between the Top of the Cooking Platform and Unprotected Wood or Metal Cabinet 13 33 cm Max Depth For Cabinet Installed Above Cooktop MODEL A B Minimum Clearance from Left Side C Minimum Clearance from Right Side 30 Cooktop 30 76 2 cm 9 22 9 cm 9 22 9 cm 2 5 7 cm Min From Counter Edge to Front Edge of Cutout...

Страница 4: ...mounting hardware must be used to secure the built in oven to the cabinets Refer to the built in oven installation instructions Side filler panels are necessary to isolate the unit from adjoining cabinets Panel height should allow for installation of approved cooktop models See Typical Gas Cooktop Installation Over an Electric Built in Oven Installed Under the Counter on next page 36 91 4 cm Min J...

Страница 5: ...alled Under the Counter FRONT VIEW SIDE VIEW Figure 4 Wall Oven Cabinet GAS COOKTOP GAS COOKTOP WALL OVEN Pressure Regulator Flare Union Flare Union Flexible Connector Cabinet sides or filler panel Manifold Pipe Manual Shutoff Valve To be accessible for shut off valve operation 18 45 7 cm Max Approx 6 16 5 cm ...

Страница 6: ...converting to LP gas is supplied with your cooktop The kit is marked FOR LP PROPANE GAS CONVERSION The conversion must be performed by a qualified service technician in accordance with the kit instructions and all local codes and requirements Failure to follow instructions could result in serious injury or property damage The qualified agency performing this work assumes responsibility for the con...

Страница 7: ...s individual manual shutoff valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psig 3 5 kPa or 14 water column Isolate the cooktop from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa or 1...

Страница 8: ... protected by a 15 amp circuit breaker or time delay fuse Do not use an extension cord with this cooktop Grounding Instructions IMPORTANT Please read carefully For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall receptacle see Figure 9 to minimize the possibility o...

Страница 9: ...rclockwise to increase flame size Turn the screw clockwise to decrease flame size Adjust flame until you can quickly turn knob from HIGH to LOWEST POSITION without extinguishing the flame Flame should be as small as possible without going out Note Air mixture adjustment is not required on surface burners When All Hookups are Complete Make sure all controls are left in the OFF position Make sure th...

Страница 10: ...WIRING DIAGRAM ...

Страница 11: ...GAS COOKTOP INSTALLATION INSTRUCTIONS 11 NOTES ...

Страница 12: ...GAS COOKTOP INSTALLATION INSTRUCTIONS 12 NOTES ...

Отзывы: