GAS COOKTOP INSTALLATION INSTRUCTIONS

8

7. Check Operation

Refer to the

 Use and Care Guide 

packaged with 

the cooktop for operating instructions and for care 

and cleaning of your cooktop.

1.  Remove foam caps.
2.  Turn on Electrical power and Open main 

Shutoff gas Valve

3.  Check the Igniters

 

Operation of electric igniters should be 

checked after cooktop and supply line 

connectors have been carefully checked for 

leaks and the cooktop has been connected to 

electric power. 

 

To operate the surface burner

:

A.  Push in and turn a surface burner knob 

to the lITE position. You will hear a small 

ticking noise; this is the sound of the 

electric ignitor which lights the burner.

B.  After the burner lights, turn to the desired 

flame size. The controls do not have to be 

set at a particular mark. Use the marks as 

a guide and adjust the flame as needed. 

6. Electrical Requirements

120 volt, 60 Hertz, properly grounded branch 

circuit protected by a 15 amp circuit breaker or 

time delay fuse. 

Do not use an extension cord 

with this cooktop.

grounding Instructions

IMPORTANT

 Please read carefully.

For personal safety, this appliance must be 

properly grounded.

The power cord of this appliance is equipped with 

a 3-prong (grounding) plug which mates with a 

standard 3-prong grounding wall receptacle (see 

Figure 9) to minimize the possibility of electric 

shock hazard from the appliance.
The wall receptacle and circuit should be checked 

by a qualified electrician to make sure the 

receptacle is properly grounded.
Where a standard 2-prong wall receptacle is 

installed, it is the personal responsibility and 

obligation of the consumer to have it replaced by 

a properly grounded 3-prong wall receptacle.

Preferred Method

Grounding type

wall receptacle

Do not, under any 

circumstances, 

cut, remove, 

or bypass the 

grounding prong.

Power supply 

cord with 3-prong 

grounding plug.

Do not, under any circumstances, cut or 

remove the third (ground) prong from the 

power cord.

WARNING

 

Disconnect electrical supply cord 

from wall receptacle before servicing cooktop.

Figure 9

Содержание 318205454 (1302)

Страница 1: ...cm space underneath the cooktop for connection to gas supply line NOTE Wiring diagrams for this cooktop are enclosed in this booklet Printed in Canada Appliances Installed in the state of Massachusetts This Appliance can only be installed in the state of Massachusetts by a Massachusetts licensed plumber or gas fitter This appliance must be installed with a three 3 foot 36 in long flexible gas conn...

Страница 2: ...read it carefully Air curtain or other overhead hoods which operate by blowing a downward air flow on to a range shall not be used in conjunction with gas ranges other than when the hood and range have been designed tested and listen by an independent test laboratory for use in combination with each other Be sure your cooktop is installed and grounded properly by a qualified installer or service t...

Страница 3: ... Cutout and Nearest Combustible Surface Above Countertop Clearance 30 76 2 cm Min Clearance Between the Top of the Cooking Platform and Unprotected Wood or Metal Cabinet 13 33 cm Max Depth For Cabinet Installed Above Cooktop MODEL A B Minimum Clearance from Left Side C Minimum Clearance from Right Side 30 Cooktop 30 76 2 cm 9 22 9 cm 9 22 9 cm 2 5 7 cm Min From Counter Edge to Front Edge of Cutout...

Страница 4: ...mounting hardware must be used to secure the built in oven to the cabinets Refer to the built in oven installation instructions Side filler panels are necessary to isolate the unit from adjoining cabinets Panel height should allow for installation of approved cooktop models See Typical Gas Cooktop Installation Over an Electric Built in Oven Installed Under the Counter on next page 36 91 4 cm Min J...

Страница 5: ...alled Under the Counter FRONT VIEW SIDE VIEW Figure 4 Wall Oven Cabinet GAS COOKTOP GAS COOKTOP WALL OVEN Pressure Regulator Flare Union Flare Union Flexible Connector Cabinet sides or filler panel Manifold Pipe Manual Shutoff Valve To be accessible for shut off valve operation 18 45 7 cm Max Approx 6 16 5 cm ...

Страница 6: ...converting to LP gas is supplied with your cooktop The kit is marked FOR LP PROPANE GAS CONVERSION The conversion must be performed by a qualified service technician in accordance with the kit instructions and all local codes and requirements Failure to follow instructions could result in serious injury or property damage The qualified agency performing this work assumes responsibility for the con...

Страница 7: ...s individual manual shutoff valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psig 3 5 kPa or 14 water column Isolate the cooktop from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa or 1...

Страница 8: ... protected by a 15 amp circuit breaker or time delay fuse Do not use an extension cord with this cooktop Grounding Instructions IMPORTANT Please read carefully For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall receptacle see Figure 9 to minimize the possibility o...

Страница 9: ...rclockwise to increase flame size Turn the screw clockwise to decrease flame size Adjust flame until you can quickly turn knob from HIGH to LOWEST POSITION without extinguishing the flame Flame should be as small as possible without going out Note Air mixture adjustment is not required on surface burners When All Hookups are Complete Make sure all controls are left in the OFF position Make sure th...

Страница 10: ...WIRING DIAGRAM ...

Страница 11: ...GAS COOKTOP INSTALLATION INSTRUCTIONS 11 NOTES ...

Страница 12: ...GAS COOKTOP INSTALLATION INSTRUCTIONS 12 NOTES ...

Отзывы: