equIrements

• 

Dacor

 

®

 cannot be held responsible for damage to 

property or injury to persons caused by failure to 
comply with the installation, maintenance, and safety 
instructions contained in this handbook.

• 

Statutory regulations and the connection specifications 
issued by the local power supply company must be 
strictly observed.

• 

The coffee system is supplied with a 60” (1524mm) 
long power cord terminated by a three-prong plug. The 
power cord is intended to be plugged directly into a 
dedicated, wall-mounted electrical receptacle.

• 

The correct voltage, frequency, and amperage must be 
supplied to the electrical receptacle from a grounded, 
dedicated, single phase circuit that is protected by a 
properly sized circuit breaker or time-delay fuse. If one 
is not installed, call a licensed electrician.

• 

The coffee system must be installed at a safe distance 
from other sources of heat, such as home appliances, 
in order to avoid an excessive rise in temperature.

• 

For ventilation purposes, there must be a slot near the 
top of the cabinet back. The minimum dimensions are 
4” X 12” (10.0 X 30.0cm).

NOTES:

1. 

The electrical box and water shut off valve (for model 
CM24P) should be located in an adjacent cabinet.

2. 

The electric cord is located in the lower right rear 
corner on the back of the unit.

3. 

To connect the water supply to a hose, you will need a 
hose fitting with a 1/4-19 BSPP female thread.

4. 

Do not install the unit in a free-standing cabinet.

5. 

To prevent damage to the control panel door, do 
not set the appliance on the floor or counter prior to 
installation.

d

etermIne

 W

ater

 h

ardness

Before installing the coffee system, determine the water 
hardness level by doing one of the following:

• 

Use the water hardness test strips included with the 
appliance to test the water hardness level of the water 
supplied to the building where the coffee system will be 
installed. Dip the strip in a cup of water from a faucet 
and read the hardness level according to the color key 
included with the test strips.

• 

Call the local water company. Ask them for the water 
hardness level of the water supplied to the building 
where the coffee system will be installed.

For Model CM24T (Tank Model):

• 

If the water hardness level is above four grains per 
gallon (4 gpg) you must use filtered water with a 
hardness of 4 gpg or less. Do not use distilled water.

• 

If the water hardness level is below 4 gpg, you may 
use tap water in the coffee system. Filtered water is 
recommended for better taste.

For Model CM24P (Plumbed Model):

• 

If the water hardness is above 4 grains per gallon 
(4gpg) contact a water treatment specialist. Have a 
water treatment system installed that lowers the water 
hardness level to 4 gpg or less.

• 

Regardless of the type of water treatment system 
installed, Dacor highly recommends installation of 
a Dacor ACFS flushing system (not included) with 
model CM24P. The coffee system requires periodic 
decalcification regardless of the water hardness level. 
The filter head included in the flushing system kit is 
required to perform this process for model CM24P.

• 

Attach the included bypass module to the filter head. If 
the water supply to the filter head is unfiltered, you may 
attach the optional filter cartridge (Dacor P/N ACWF) 
instead to improve water taste. To prevent leaks over 
time, 

DO NOT

 use the JT-2 flushing cartridge for 

everyday use.

Dacor ACFS flushing system kit installation. 

Install for model CM24P.

Bypass Module

Filter Head

To coffee system

To house water 
supply or whole 
house water filter

Installation of optional filter cartridge kit for model 

CM24P with a water supply having no existing filter 

system.

Optional Filter 
Cartridge
(Dacor P/N ACWF)

Filter Head

To coffee system

To house 
water supply

Содержание CM24T

Страница 1: ...Installation Instructions Automatic Coffee System For use with models CM24T CM24P Part No 65464 Rev F...

Страница 2: ......

Страница 3: ...safe practices that COULD result in minor personal injury or property damage IMPORTANT Installer In the interest of safety and to minimize problems read these installation instructions completely and...

Страница 4: ...he coffee system Children could be burned or injured while climb ing on the appliance Do not tamper with the controls The coffee system must be cleaned thoroughly according to the Routine Cleaning Ins...

Страница 5: ...on how to open the front panel and brewing unit doors Serial Number Label Design Specifications Overall Dimensions 18 3 16 462mm 22 1 16 560mm 17 9 16 445mm 21 9 16 548mm 13 16 20mm 23 1 2 596mm 17 5...

Страница 6: ...with the appliance to test the water hardness level of the water supplied to the building where the coffee system will be installed Dip the strip in a cup of water from a faucet and read the hardness...

Страница 7: ...5 4mm Max recommended distance to floor of room 36 914mm Ventilation opening in back of cabinet 4 X 12 Min 100mm X 300mm During normal operation the user must have access to the top of the unit The us...

Страница 8: ...O ring and two of the quick release fittings as shown Pressure Regulator Mounting Control Knob Remove the coffee system from the packaging and inspect it for damage Do not install a damaged system In...

Страница 9: ...k release fitting to the second hose With the main water valve closed attach the quick release fitting to the water line from decalcification kit You can connect to a house water supply hose or water...

Страница 10: ...he coffee system to slide in and out of the cabinet for loading the coffee bins and for maintenance To install the cabinet glides Determine the number of shims required to mount the cabinet glide asse...

Страница 11: ...use and care manual On model CM24T clean the water tank Put a sauce pan under the drink dispenser Make one of each type of drink in the Basic Operation Instructions section of the use and care manual...

Страница 12: ...ied in the use and care manual Is the coffee system connected to a dedicated grounded power receptacle See Location Requirements on page 4 Is the steam barrier installed See Page 6 Is the pressure reg...

Страница 13: ...11 Notes...

Страница 14: ...12 Notes...

Страница 15: ......

Страница 16: ...Copyright 2007 by Dacor Inc All rights reserved Web Site www Dacor com Phone 800 793 0093...

Отзывы: