background image

I

nstallatIon

 I

nstructIons

I

nstallIng

 

the

 c

offee

 s

ystem

 

In

 

the

 

c

abInet

• 

While supporting the coffee system from below, insert it 
into the cabinet cutout. As you insert it into the cabinet, 
line up the glides on the appliance with the cabinet 
glides. The system should glide on the rails when slight 
pressure is applied to the front of the coffee system. If 
it does not glide smoothly, check the distance between 
the glides again. See page 8.

• 

As you slide the coffee system into the cabinet the  
locking tab on the glides will engage.

Locking Tab 

Locking Tab Location

v

erIfyIng

 o

peratIon

• 

Plug the coffee system into the dedicated, properly 
grounded, 3-prong receptacle.

• 

Turn the light on and off to test it.

• 

Turn on the power switch, located below the control 
panel. 

• 

On model CM24P (plumbed model): turn on the water 
supply at the shut-off valve. Check to make sure the 
pressure regulator is set between 1.5 bars to 3 bars 
pressure. Adjust the regulator if necessary.

• 

On model CM24T (tank model): Fill the tank with 
filtered water (4 gpg maximum water hardness, do not 
use distilled water).

• 

Push the hot water button. Wait about 
six seconds.

• 

Continue to push the hot water button 
every six seconds until air bubbles no 
longer come out of the dispenser and about six ounces 
of water is dispensed.

• 

Clean the coffee system according to the Routine 
Cleaning and Milk Cleaning instructions in the use and 
care manual. On model CM24T, clean the water tank. 

• 

Put a sauce pan under the drink dispenser.

• 

Make one of each type of drink in the Basic Operation 
Instructions section of the use and care manual.

If the coffee system does not operate properly, follow 
these troubleshooting steps:

1. 

Verify that power and water are being supplied to the 
coffee system. On CM24T, make sure the water tank 
is full.

2. 

Make sure that the coffee bins have been properly 
filled according to the Basic Operating Instructions in 
the use and care manual.

3. 

Check the regulator to make sure it is properly 
adjusted. Air in the system during initial operation can 
cause the initial adjustment to be incorrect.

4. 

Make sure that water flows through the pressure 
regulator in the right direction.

5. 

Repeat the above test.

6. 

If the appliance still does not work, contact an 
authorized Dacor

 

®

 service company. If you are 

unable to locate a Dacor Service company, please 
contact Dacor at (800) 793-0093, or visit us on the 
web at www.Dacor.com. Do not attempt to repair 
the appliance yourself. Dacor is not responsible for 
service required to correct a faulty installation. 

I

f

 y

ou

 n

eed

 

to

 r

emove

 

the

 c

offee

 

s

ystem

 f

rom

 

the

 c

abInet

Should the coffee system need to be removed from its 
location:

• 

Disconnect the power plug from the power receptacle.

• 

Press the respective locking tabs on the glides and 
remove the appliance, supporting it from below.

 CAUTION

Pour only roasted, unflavored coffee into the coffee bean 
container. Any other kind of coffee, e.g. coffee which has 
already been ground, will damage the grinder.

Содержание CM24T

Страница 1: ...Installation Instructions Automatic Coffee System For use with models CM24T CM24P Part No 65464 Rev F...

Страница 2: ......

Страница 3: ...safe practices that COULD result in minor personal injury or property damage IMPORTANT Installer In the interest of safety and to minimize problems read these installation instructions completely and...

Страница 4: ...he coffee system Children could be burned or injured while climb ing on the appliance Do not tamper with the controls The coffee system must be cleaned thoroughly according to the Routine Cleaning Ins...

Страница 5: ...on how to open the front panel and brewing unit doors Serial Number Label Design Specifications Overall Dimensions 18 3 16 462mm 22 1 16 560mm 17 9 16 445mm 21 9 16 548mm 13 16 20mm 23 1 2 596mm 17 5...

Страница 6: ...with the appliance to test the water hardness level of the water supplied to the building where the coffee system will be installed Dip the strip in a cup of water from a faucet and read the hardness...

Страница 7: ...5 4mm Max recommended distance to floor of room 36 914mm Ventilation opening in back of cabinet 4 X 12 Min 100mm X 300mm During normal operation the user must have access to the top of the unit The us...

Страница 8: ...O ring and two of the quick release fittings as shown Pressure Regulator Mounting Control Knob Remove the coffee system from the packaging and inspect it for damage Do not install a damaged system In...

Страница 9: ...k release fitting to the second hose With the main water valve closed attach the quick release fitting to the water line from decalcification kit You can connect to a house water supply hose or water...

Страница 10: ...he coffee system to slide in and out of the cabinet for loading the coffee bins and for maintenance To install the cabinet glides Determine the number of shims required to mount the cabinet glide asse...

Страница 11: ...use and care manual On model CM24T clean the water tank Put a sauce pan under the drink dispenser Make one of each type of drink in the Basic Operation Instructions section of the use and care manual...

Страница 12: ...ied in the use and care manual Is the coffee system connected to a dedicated grounded power receptacle See Location Requirements on page 4 Is the steam barrier installed See Page 6 Is the pressure reg...

Страница 13: ...11 Notes...

Страница 14: ...12 Notes...

Страница 15: ......

Страница 16: ...Copyright 2007 by Dacor Inc All rights reserved Web Site www Dacor com Phone 800 793 0093...

Отзывы: