background image

ENGLISH 

16 

 

 

 

CONTENTS 

page 

1. 

 

GENERAL 

16

 

1.1. 

 

Pump description 

16

 

2. 

 

APPLICATIONS 

16

 

3. 

 

PUMPED FLUIDS 

16 

4. 

 

TECHNICAL DATA AND RANGE OF USE 

17

 

5. 

 

MANAGEMENT 

17

 

5.1. 

 

Storage 

17

 

5.2. 

 

Transport 

17

 

5.3. 

 

Dimensions and weights 

17

 

6. 

 

WARNINGS 

17

 

6.1. 

 

Checking pump/motor shaft rotation 

17

 

6.2. 

 

New systems 

17

 

6.3. 

 

Protections 

17

 

6.3.1   

Moving parts 

17

 

6.3.2   

Noise level 

18

 

6.3.3   

Hot and cold parts 

18

 

7. 

 

INSTALLATION 

18

 

8. 

 

ELECTRICAL CONNECTION 

19

 

9. 

 

STARTING UP 

19

 

10. 

 

STARTING/STOPPING 

19 

11. 

  PRECAUTIONS 

20

 

12. 

  MAINTENANCE AND CLEANING 

20

 

12.1. 

  Periodic checks 

20

 

12.2.

 

 

Shaft seal 

20

 

12.2.1 

  Mechanical seal 

20

 

12.3. 

 

Greasing the bearings 

20 

12.4. 

  Changing the seal 

20

 

12.4.1 

  Preparing disassembly 

20

 

12.4.2 

  Changing the mechanical seal 

20 

13. 

 

MODIFICATIONS AND SPARE PARTS 

21 

14. 

 

TROUBLESHOOTING 

21 

 

1. 

GENERAL 

 

 

The pump may be installed in either horizontal or vertical position, as long as the motor is always above the 

pump. 

1.1.  Pump description: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. 

APPLICATIONS 

Single-stage stub shaft type centrifugal motor-driven pumps with a spiral body, dimensions in accordance with DIN 24255 - EN 733 and flanged DIN 

2533 (DIN 2532 per DN 200). Designed and built with advanced characteristics, they are outstanding for their particular performances which ensure 

maximum yield while guaranteeing absolute reliability and sturdy construction. They cover a wide range of applications, such as water supply, 

circulation of hot and cold water in heating, air-conditioning and refrigerating systems, transfer of liquids in agriculture, market gardening and industry. 

Also suitable for use in fire-fighting sets. 

 

3. 

PUMPED FLUIDS 

 

The machine has been designed and built for pumping clean, pure and aggressive fluids, on condition that in the latter 

case the compatibility of the pump construction materials is checked and that the motor used has sufficient power for 

the specific gravity and the viscosity of the fluid.  

 

Example:

 

-

 

 - 

 

 / 

 

/

 

Type range:

 

TWO-POLE MOTOR = P

 

FOUR-POLE MOTOR = M

 

With standardised motor and coupling

 

Nominal diameter of discharge port

 

Nominal impeller diameter

 

Actual impeller diameter

 

Cod for materials:

 

A = Cast iron

 

B = Cast iron with bronze impeller

 

Wear rings ( only when there is )

 

Code for shaft seal:

 

Motor power in kW

 

Poles:

 

4 = 4 poles

 

2 = 2 poles

 

50

 

 NKM

 

250

 

263

 

G

 

     A

 

W

 

/ BAQE

 

4

 

/ 4

 

 

Содержание NKM-G

Страница 1: ...N F R INSTALLATION UND WARTUNG INSTRUCTIES VOOR INGEBRUIKNAME EN ONDERHOUD INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO INSTALLATIONS OCH UNDERH LLSANVISNING MONTAVIMO IR PRIE I ROS INSTRUKCIJ...

Страница 2: ...GE 125 250 NKM GE 150 200 NKP 32 125 1 NKP 32 125 NKP 32 160 1 NKP 32 160 NKP 32 200 1 NKP 32 200 NKP 40 125 NKP 40 160 NKP 40 200 NKP 40 250 NKP 50 125 NKP 50 160 NKP 50 200 NKP 50 250 NKP G 32 125...

Страница 3: ...ITALIANO pag 02 FRAN AIS page 09 ENGLISH page 16 DEUTSCH Seite 22 NEDERLANDS bladz 29 ESPA OL p g 36 SVENSKA sid 43 49 LIETUVI KAI psl 56 ROMANA pag 62 PORTUGU S p g 68 MAGYAR oldal 75 82 88 97...

Страница 4: ...Linija Linie Linha T pvonal Collegamento a TRIANGOLO Branchement TRIANGLE DELTA starting Driehoekaansluiting DREIECK Schaltung Conexi n de TRI NGULO DELTA anslutning Trikampis jungimas Conexiune TRIU...

Страница 5: ...dimensions in accordance with DIN 24255 EN 733 and flanged DIN 2533 DIN 2532 per DN 200 Designed and built with advanced characteristics they are outstanding for their particular performances which en...

Страница 6: ...Use suitable hemp or synthetic ropes only if the part can be easily slung as indicated in fig 5 2 If an eyebolt is provided on the motor it must not be used for lifting the whole assembly fig 5 2 5 3...

Страница 7: ...ice to place the pump as close as possible to the liquid to be pumped It is advisable to use a suction pipe with a diameter larger than that of the intake aperture of the electropump If the head at in...

Страница 8: ...he switch over time from star to delta is as short as possible and that it falls within table 8 1 on page 105 8 2 Before opening the terminal board and working on the pump ensure that the power has be...

Страница 9: ...legal requirements on the disposal of any harmful fluids must also be complied with After a long period of operation there may be difficulties in removing the parts in contact with water to do this u...

Страница 10: ...y side or install a larger motor 5 The motor protection trips too frequently A Ensure that the environment temperature is not too high B Check the calibration of the protection C Check the state of th...

Страница 11: ...MEC 160M 15 32 MEC 100L 2 2 10 6 MEC 160L 18 5 40 MEC 100L 3 12 8 MEC 180M 22 50 MEC 112M 4 20 10 MEC 200L 30 80 MEC 132S 5 5 12 MEC 132M 7 5 20 MEC 160M 11 25 MEC 160L 15 32 MEC 180M 18 5 40 MEC 180...

Страница 12: ...LOS COJINETES CONSTRUCCI N EST NDAR KLASSIFICERING AV LAGER STANDARDUTF RANDE GUOLI KLASIFIKAVIMAS STANDARTIN KONSTRUKCIJA CLASIFICARE RULMEN I CONSTRUC IE STANDARD CLASSIFICA O DOS ROLAMENTOS CONSTRU...

Страница 13: ...Bearings Lager Lagers Cojinetes Lager Guoliai Rulmen i Rolamentos Csap gyak NDE Molla di precarico Ressort de pr charge Preloading spring Vorspannfeder Voorbelastingsveer Muelle de precarga F rbelast...

Страница 14: ...Intervalos at s lubrifica es seguintes para temperaturas at 70 C horas de funcionamento jra zs roz si sz net a 70 fokot meghalad h m rs kleten munkav gz si r k 70 C 70 70 C 3000 RPM 1500 RPM 1000 RPM...

Страница 15: ...147 60 1 888 70 3 014 80 4 67 90 7 035 100 10 33 110 14 83 120 20 85 130 28 744 140 38 97 150 52 Pb _ Pb Pv Y4 Yt Pb e Pv in mCA Fig 6 pb 7 8 9 10 0 500 1000 1500 2000 2500 3000 m mCA Fig 7 pV 0 50 10...

Страница 16: ...aan a 2 x DN Nominale diameter DAB adviseert om 4 x DN aan te houden omdat daardoor de drukmeting nauwkeuriger wordt La distancia de las medidas de la presi n seg n la normativa UNI EN ISO 9906 8 2 1...

Страница 17: ...23 3 34 8 NKM 50 125 6 5 6 8 NKM 50 160 10 8 10 4 NKM 50 200 16 8 19 NKM 50 250 23 8 33 NKM G 32 125 1 6 2 6 4 NKM G 32 125 7 6 6 NKM G 32 160 1 8 9 9 2 NKM G 32 160 9 4 11 5 NKM G 32 200 1 12 7 19 8...

Страница 18: ...4 8 NKM GE 50 125 6 5 6 8 NKM GE 50 160 10 8 10 4 NKM GE 50 200 16 8 19 NKM GE 50 250 23 8 33 NKM GE 65 125 6 5 6 4 NKM GE 65 160 10 5 11 4 NKM GE 65 200 17 16 9 NKM GE 65 250 24 1 22 8 NKM GE 65 315...

Страница 19: ...41 39 9 NKP G 40 200 57 54 NKP G 40 250 96 108 NKP G 50 125 28 29 8 NKP G 50 160 39 5 42 NKP G 50 200 67 5 71 NKP G 50 250 92 5 106 NKP G 65 125 23 5 25 7 NKP G 65 160 40 43 NKP G 65 200 68 5 75 NKP G...

Страница 20: ...poles 60 Hz NKM G 40 330 39 NKM G 50 330 38 NKM G 65 400 55 NKM G 80 400 61 NKM G 100 400 59 NKM G 125 330 38 NKM G 125 400 61 NKM G 150 330 37 NKM G 150 400 59 NKM G 200 200 12 NKM G 200 250 20 NKM G...

Отзывы: