14. TROUBLESHOOTING
FAULT
CHECK (possible cause)
REMEDY
1.
The motor does not start
and makes no noise.
A.
Check the protection fuses.
B.
Check the electric connections.
C.
Check that the motor is live
A.
If they are burnt-out, change them.
−
If the fault is repeated immediately this means that the
motor is short circuiting..
2.
The motor does not start
but makes noise.
A.
Ensure that the mains voltage corresponds to the
voltage on the data plate.
B.
Check that the connections have been made
correctly.
C.
Check that all the phases are present on the
terminal board.
D.
The shaft is blocked. Look for possible obstructions
in the pump or motor.
B. Correct any errors.
C. If not, restore the missing phase.
D. Remove the obstruction.
3.
The motor turns with
difficulty.
A.
Check the supply voltage which may be
insufficient.
B.
Check whether any moving parts are scraping
against fixed parts.
C.
Check the state of the bearings.
B.
Eliminate the cause of the scraping.
C.
Change any worn bearings.
4.
The (external) motor
protection trips
immediately after
starting.
A.
Check that all the phases are present on the
terminal board.
B.
Look for possible open or dirty contacts in the
protection.
C.
Look for possible faulty insulation of the motor,
checking the phase resistance and insulation to
earth.
D.
The pump is functioning above the work point for
which it was intended.
E.
The protection tripping values are wrong.
F.
The viscosity or density of the pumped fluid are
different from those used in the design phase.
A.
If not, restore the missing phase.
B.
Change or clean the component concerned.
C.
Look for possible faulty insulation of the motor, checking
the phase resistance and insulation to earth.
D.
Set the work point to suit the pump characteristics.
E.
Check the set values on the motor protector: alter them
or change the component if necessary.
F.
Reduce the flow rate with a shutter on the delivery side
or install a larger motor.
5.
The motor protection
trips too frequently.
A.
Ensure that the environment temperature is not too
high.
B.
Check the calibration of the protection.
C.
Check the state of the bearings.
D.
Check the motor rotation speed.
A.
Provide suitable ventilation in the environment where
the pump is installed.
B.
Calibrate at a current value suitable for the motor
absorption at full load.
C.
Change any worn bearings.
6.
The pump does not
deliver.
A.
The pump has not been correctly primed.
B.
Check that the direction of rotation of the three-
phase motors is correct.
C.
Difference in suction level too high.
D.
The diameter of the intake pipe is insufficient or the
length is too long.
E.
Foot valve blocked.
A.
Fill the pump and the intake pipe with water. Prime the
pump.
B.
Invert the connection of two supply wires.
C.
See point 8 of the instructions on ”Installation”.
D.
Replace the intake pipe with one with a larger diameter.
E.
Clean the foot valve.
7.
The pump does not
prime.
A.
The intake pipe or the foot valve is taking in air.
B.
The downward slope of the intake pipe favours the
formation of air pockets.
A.
Eliminate the phenomenon, checking the intake pipe
accurately, and prime again.
B.
Correct the inclination of the intake pipe.
8.
The pump supplies
insufficient flow.
A.
Blocked foot valve.
B.
The impeller is worn or blocked.
C.
The diameter of the intake pipe is insufficient.
D.
Check that the direction of rotation is correct.
A.
Clean the foot valve.
B.
Change the impeller or remove the obstruction.
C.
Replace the pipe with one with a larger diameter.
D.
Invert the connection of two supply wires.
9.
Invert the connection of
two supply wires.
A.
Intake pressure too low.
B.
Intake pipe or pump partly blocked by impurities.
B.
Clean the intake pipe and the pump.
10.
The pump turns in the
opposite direction when
switching off.
A.
Leakage in the intake pipe.
B.
Foot valve or check valve faulty or blocked in partly
open position.
A.
Eliminate the fault.
B.
Repair or replace the faulty valve.
11.
The pump vibrates and
operates noisily.
A.
Check that the pump and/or the pipes are firmly
anchored.
B.
There is cavitation in the pump (see point 8,
paragraph on INSTALLATION).
C.
Presence of air in the pump or in the intake
manifold.
D.
Pump-motor alignment incorrectly performed.
A.
Fasten any loose parts.
B.
Reduce the intake height or check for load losses. Open
the intake valve.
C.
Bleed the intake pipes and the pump.
D.
Repeat the procedure described in paragraph 7.2.