4. 

 

TECHNICAL DATA AND RANGE OF USE 

Pump 

 

Liquid temperature range:

 

from -10°C to +140°C standard pumps 

from -25°C to +140°C oversize pumps 

 

Rotation speed: 

970-1450-2900 1/min 

 

Flow rate: 

from 1 m³/h to 1100 m³/h depending on the model 

 

Head up – Hmax (m): 

pag. 110 

 

Maximum environment temperature: 

+40°C 

 

Storage temperature: 

-10°C +40°C 

 

Relative humidity of the air: 

max 95% 

 

Maximum working pressure (including any pressure at intake): 

16 Bar - 1600 kPa (for DN 200- DN 250 max 10 Bar-1000 kPa) 

 

Weight: 

See plate on package 

Motor 

 

Supply voltage:      

see electrical data plate 

 

Degree of motor protection : 

IP55 

 

Thermal class : 

 

Absorbed power : 

see electric data plate 

 

Motor construction : 

in conformity with Standards CEI 2 - 3  

 

Class AM line fuses: see table 4.1.  page 104 

 

 

If a fuse trips which protects a three-phase motor, it is recommended to change the other two fuses as well, not only 

the one that is burnt-out. 

 

5. 

MANAGEMENT 

5.1.  Storage 

All the pumps/electropumps must be stored indoors, in a dry, vibration-free and dust-free environment, possibly with constant air humidity. 

They are supplied in their original packaging and must remain there until the time of installation, with the intake and delivery mouths closed 

with the special adhesive disc supplied. In the case of long storage, or if the pump is stored after a certain period of operation, only the parts 

made of low-percentage alloy materials, such as cast iron GG-25, GGG-40 which have been wet with the pumped fluid, should be kept in the 

special preserving mediums available on the market. 

5.2.  Transport 

Avoid subjecting the products to needless jolts or collisions. 

To lift and transport the unit, use lifting equipment and the pallet supplied standard (if 

applicable). 

Use suitable hemp or synthetic ropes only if the part can be easily slung, as indicated 

in fig.5.2.  If an eyebolt is provided on the motor, it must not be used for lifting the 

whole assembly. 

 

 

 

 

 

 

 

                                                             (fig. 5.2.) 

5.3.  Dimensions and weights 

The adhesive label on the package indicates the total weight of the electropump.   

 

6. 

WARNINGS 

6.1.  Checking pump/motor shaft rotation 

Before

 

installing the electropump,

 it is good practice to check that the pump shaft and/or the motor are moving freely. For this purpose, if 

the pumps are supplied without a motor, check them by turning the pump coupling by hand. If the electropump is supplied as a complete unit, 

check by turning the coupling by hand after having removed the coupling cover. When you have finished checking, put the coupling cover 

back in its original position. 

 

Do not force the shaft or the fan of the motor (if supplied) with pliers or other tools to try to free the pump, but look 

for the cause of the blockage. 

6.2.   

New systems 

Before running new systems the valves, pipes, tanks and couplings must be cleaned accurately.  Often welding waste, flakes of oxide or other 

impurities fall off after only a certain period of time.  To prevent them from getting into the pump they must be caught by suitable filters.  The 

free surface of the filter must have a section at least 3 times larger than the section of the pipe on which the filter is fitted, so as not to create 

excessive load losses.  We recommend the use of TRUNCATED CONICAL filters made of corrosion-resistant materials (SEE DIN 4181): 

  

 

 

(Filter for intake pipe) 

1) Filter body 

2) Narrow mesh filter 

3) Differential pressure gauge 

4) Perforated sheet 

5) Pump intake aperture 

6.3. 

Protections 

6.3.1. 

Moving parts

 

In accordance with accident-prevention regulations, all moving parts (fans, couplings, etc.) must be accurately protected with 

special devices (fan covers, coupling covers) before operating the pump.

 

 

1

 

2

 

3

 

4

 

5

 

  

Содержание NKM-G

Страница 1: ...N F R INSTALLATION UND WARTUNG INSTRUCTIES VOOR INGEBRUIKNAME EN ONDERHOUD INSTRUCCIONES PARA LA INSTALACION Y EL MANTENIMIENTO INSTALLATIONS OCH UNDERH LLSANVISNING MONTAVIMO IR PRIE I ROS INSTRUKCIJ...

Страница 2: ...GE 125 250 NKM GE 150 200 NKP 32 125 1 NKP 32 125 NKP 32 160 1 NKP 32 160 NKP 32 200 1 NKP 32 200 NKP 40 125 NKP 40 160 NKP 40 200 NKP 40 250 NKP 50 125 NKP 50 160 NKP 50 200 NKP 50 250 NKP G 32 125...

Страница 3: ...ITALIANO pag 02 FRAN AIS page 09 ENGLISH page 16 DEUTSCH Seite 22 NEDERLANDS bladz 29 ESPA OL p g 36 SVENSKA sid 43 49 LIETUVI KAI psl 56 ROMANA pag 62 PORTUGU S p g 68 MAGYAR oldal 75 82 88 97...

Страница 4: ...Linija Linie Linha T pvonal Collegamento a TRIANGOLO Branchement TRIANGLE DELTA starting Driehoekaansluiting DREIECK Schaltung Conexi n de TRI NGULO DELTA anslutning Trikampis jungimas Conexiune TRIU...

Страница 5: ...dimensions in accordance with DIN 24255 EN 733 and flanged DIN 2533 DIN 2532 per DN 200 Designed and built with advanced characteristics they are outstanding for their particular performances which en...

Страница 6: ...Use suitable hemp or synthetic ropes only if the part can be easily slung as indicated in fig 5 2 If an eyebolt is provided on the motor it must not be used for lifting the whole assembly fig 5 2 5 3...

Страница 7: ...ice to place the pump as close as possible to the liquid to be pumped It is advisable to use a suction pipe with a diameter larger than that of the intake aperture of the electropump If the head at in...

Страница 8: ...he switch over time from star to delta is as short as possible and that it falls within table 8 1 on page 105 8 2 Before opening the terminal board and working on the pump ensure that the power has be...

Страница 9: ...legal requirements on the disposal of any harmful fluids must also be complied with After a long period of operation there may be difficulties in removing the parts in contact with water to do this u...

Страница 10: ...y side or install a larger motor 5 The motor protection trips too frequently A Ensure that the environment temperature is not too high B Check the calibration of the protection C Check the state of th...

Страница 11: ...MEC 160M 15 32 MEC 100L 2 2 10 6 MEC 160L 18 5 40 MEC 100L 3 12 8 MEC 180M 22 50 MEC 112M 4 20 10 MEC 200L 30 80 MEC 132S 5 5 12 MEC 132M 7 5 20 MEC 160M 11 25 MEC 160L 15 32 MEC 180M 18 5 40 MEC 180...

Страница 12: ...LOS COJINETES CONSTRUCCI N EST NDAR KLASSIFICERING AV LAGER STANDARDUTF RANDE GUOLI KLASIFIKAVIMAS STANDARTIN KONSTRUKCIJA CLASIFICARE RULMEN I CONSTRUC IE STANDARD CLASSIFICA O DOS ROLAMENTOS CONSTRU...

Страница 13: ...Bearings Lager Lagers Cojinetes Lager Guoliai Rulmen i Rolamentos Csap gyak NDE Molla di precarico Ressort de pr charge Preloading spring Vorspannfeder Voorbelastingsveer Muelle de precarga F rbelast...

Страница 14: ...Intervalos at s lubrifica es seguintes para temperaturas at 70 C horas de funcionamento jra zs roz si sz net a 70 fokot meghalad h m rs kleten munkav gz si r k 70 C 70 70 C 3000 RPM 1500 RPM 1000 RPM...

Страница 15: ...147 60 1 888 70 3 014 80 4 67 90 7 035 100 10 33 110 14 83 120 20 85 130 28 744 140 38 97 150 52 Pb _ Pb Pv Y4 Yt Pb e Pv in mCA Fig 6 pb 7 8 9 10 0 500 1000 1500 2000 2500 3000 m mCA Fig 7 pV 0 50 10...

Страница 16: ...aan a 2 x DN Nominale diameter DAB adviseert om 4 x DN aan te houden omdat daardoor de drukmeting nauwkeuriger wordt La distancia de las medidas de la presi n seg n la normativa UNI EN ISO 9906 8 2 1...

Страница 17: ...23 3 34 8 NKM 50 125 6 5 6 8 NKM 50 160 10 8 10 4 NKM 50 200 16 8 19 NKM 50 250 23 8 33 NKM G 32 125 1 6 2 6 4 NKM G 32 125 7 6 6 NKM G 32 160 1 8 9 9 2 NKM G 32 160 9 4 11 5 NKM G 32 200 1 12 7 19 8...

Страница 18: ...4 8 NKM GE 50 125 6 5 6 8 NKM GE 50 160 10 8 10 4 NKM GE 50 200 16 8 19 NKM GE 50 250 23 8 33 NKM GE 65 125 6 5 6 4 NKM GE 65 160 10 5 11 4 NKM GE 65 200 17 16 9 NKM GE 65 250 24 1 22 8 NKM GE 65 315...

Страница 19: ...41 39 9 NKP G 40 200 57 54 NKP G 40 250 96 108 NKP G 50 125 28 29 8 NKP G 50 160 39 5 42 NKP G 50 200 67 5 71 NKP G 50 250 92 5 106 NKP G 65 125 23 5 25 7 NKP G 65 160 40 43 NKP G 65 200 68 5 75 NKP G...

Страница 20: ...poles 60 Hz NKM G 40 330 39 NKM G 50 330 38 NKM G 65 400 55 NKM G 80 400 61 NKM G 100 400 59 NKM G 125 330 38 NKM G 125 400 61 NKM G 150 330 37 NKM G 150 400 59 NKM G 200 200 12 NKM G 200 250 20 NKM G...

Отзывы: