xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
702
Chapter 58
Loopback Detection
Commands
config loopdetect
{recover_timer [0 | <sec 60-1000000>] | interval <sec 1-32767> | mode [port-
based | vlan-based]}(1)
config loopdetect ports
[<portlist> | all] state [enable | disable]
enable loopdetect
disable loopdetect
show loopdetect
show loopdetect ports
{<portlist>}
config loopdetect trap
[none | loop_detected | loop_cleared | both]
config loopdetect log state
[enable | disable]
config loopdetect vlan
[<vid_list> | all] state [enable | disable]
58-1
config loopdetect
Description
This command is used to set up the loop-back detection function (LBD) for the entire switch.
Format
config loopdetect {recover_timer [0 | <sec 60-1000000>] | interval <sec 1-32767> | mode
[port-based | vlan-based]}(1)
Parameters
recover_timer
- The time interval (in seconds) used by the Auto-Recovery mechanism to decide
how long to check if the loop status is gone. The default value is 60.
0
- Zero is a special value which means to disable the auto-recovery mechanism, hence, the
user needs to recover the disabled port back manually.
<sec 60-1000000>
- Enter a value between 60 and 1000000.
interval
- The time interval (in seconds) at which device transmits all the CTP (Configuration Test
Protocol) packets to detect the loop-back event. The default setting is 10.
<sec 1-32767>
- Specifies the valid range between 1 and 32767.
mode
- Choose the loop-detection operation mode.
port-based
- In the port-based mode, the port will be shut-down (disabled) when detecting a
loop.
vlan-based
- In VLAN-based mode, the port cannot forward packets of the VLAN that detects
a loop.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To set a recover time of 0 and an interval of 20 in VLAN-based mode:
Содержание xStack
Страница 1: ......
Страница 161: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide 156 DGS 3620 28SC admin ...
Страница 503: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide 498 DGS 3620 28SC admin ...
Страница 553: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide 548 ...
Страница 565: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide 560 ...
Страница 888: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide 883 DGS 3620 28SC admin ...
Страница 1011: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide 1006 ...
Страница 1120: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide 1115 ...