xStack
®
DGS-3400 Series Layer 2 Gigabit Ethernet Managed Sw itch
250
header. This class field is a part of the packet header that is similar to the Type of Service (ToS)
or Precedence bits field of IPv4.
Flow Label
Configuring this field, in hex form, will instruct the Switch to examine the flow label field of the
IPv6 header. This flow label field is used by a source to label sequences of packets such as non-
default quality of service or real time service packets.
Source IPv6
Address
The user may specify an IP address mask for the source IPv6 address by entering the IP
address mask, in hex form.
Destination IPv6
Address
The user may specify an IP address mask for the destination IPv6 address by and entering the
IP address mask, in hex form.
Port
The Access Rule may be configured on a per-port basis by entering the port number of the
switch in the switch stack into this field. When a range of ports is to be configured, the Auto
Assign check box MUST be clicked in the Access ID field of this window. If not, the user will be
presented with an error message and the access rule will not be configured. The port list is
specified by listing the lowest switch number and the beginning port number on that switch,
separated by a colon. Then the highest switch number and the highest port number of the range
(also separated by a colon) are specified. The beginning and end of the port list range are
separated by a dash. For example, 1:3 specifies switch number 1, port 3. 2:4 specifies switch
number 2, port 4. 1:3 - 2:4 specifies all of the ports between switch 1, port 3 and switch 2, port 4
−
in numerical order. Entering
all
will denote all ports on the Switch.
RX Rate (1-
156249)
Use this to limit RX bandwidth for the profile being configured. This rate is implemented using the
following equation: 1 value = 64kbit/sec. (ex. If the user selects an RX rate of 10 then the ingress
rate is 640kbit/sec.) The user many select a value between
1
and
156249
, or
No Limit
. The
default setting is No Limit.
Time Range
Click the check box and enter the name of the Time Range settings that has been previously
configured in the
Time Range
Settings
window. This will set specific times when this access rule
will be implemented on the Switch.
Counter
Tick the check box and use the pull-down menu to employ the Counter that will count the packets
identified with this rule. Users must note that if the Counter is employed in the ACL Flow Meter
function, the Counter will automatically be disabled here, regardless of this setting.
Click
Apply
to implement the changes.
To view the settings of a previously correctly configured rule, click
View
in the
Access Rule Table
window to view the following
window:
Содержание xStack DGS-3427
Страница 134: ...xStack DGS 3400 Series Layer 2 Gigabit Ethernet Managed Switch 125 Figure 2 148 Port Speed Utilizing the Tool Tip ...
Страница 215: ...xStack DGS 3400 Series Layer 2 Gigabit Ethernet Managed Switch 206 Figure 3 68 LLDP Local Port Brief Table window ...
Страница 354: ...xStack DGS 3400 Series Layer 2 Gigabit Ethernet Managed Switch 345 Figure 6 81 JWAC Global State Configuration window ...
Страница 404: ...xStack DGS 3400 Series Layer 2 Gigabit Ethernet Managed Switch 395 Example topology ...
Страница 406: ...xStack DGS 3400 Series Layer 2 Gigabit Ethernet Managed Switch 397 ...