DXS-3400 Series Lite Layer 3 Stackable 10GbE Managed Switch Web UI Reference Guide
394
Parameter
Description
Unit
Select the Switch unit that will be used for this configuration here.
Port
Select the port used for the configuration here.
Action
Select the action that will be taken here. Options to choose from are
Add
and
Delete
.
Type
Select the type of voltage threshold. Options to choose from are
Low Alarm
,
Low
Warning
,
High Alarm
, and
High Warning
.
Value
Enter the threshold value. This value must be between 0 and 6.55 Volt.
Click the
Apply
button to accept the changes made.
DDM Bias Current Threshold Settings
This window is used to display and configure the threshold of the bias current for specific ports on the Switch.
To view the following window, click
OAM > DDM > DDM Bias Current Threshold Settings
, as shown below:
Figure 10-30 DDM Bias Current Threshold Settings Window
The fields that can be configured are described below:
Parameter
Description
Unit
Select the Switch unit that will be used for this configuration here.
Port
Select the port used for the configuration here.
Action
Select the action that will be taken here. Options to choose from are
Add
and
Delete
.
Type
Select the type of bias current threshold. Options to choose from are
Low Alarm
,
Low Warning
,
High Alarm
, and
High Warning
.
Value
Enter the threshold value. This value must be between 0 and 131 mA.
Click the
Apply
button to accept the changes made.
DDM TX Power Threshold Settings
This window is used to display and configure the threshold of TX power for specific ports on the Switch.
To view the following window, click
OAM > DDM > DDM TX Power Threshold Settings