DXS-3400 Series Lite Layer 3 Stackable 10GbE Managed Switch Web UI Reference Guide
17
Parameter
Description
interfaces this value is from 1 to 4094.
Click the
Apply
button to accept the changes made.
The fields that can be configured for
Buffer Log Settings
are described below:
Parameter
Description
Buffer Log State
Select whether the enable or disable the buffer log’s global state here. Options to
choose from are
Enable
,
Disabled
, and
Default
. When selecting the
Default
option, the buffer log’s global state will follow the default behavior.
Severity
Select the severity value of the type of information that will be logged. Options to
choose from are
0 (Emergencies)
,
1 (Alerts)
,
2 (Critical)
,
3 (Errors)
,
4
(Warnings)
,
5 (Notifications)
,
6 (Informational)
, and
7 (Debugging)
.
Discriminator Name
Enter the discriminator name used here. This name can be up to 15 characters
long.
Write Delay
Enter the log’s write delay value here. This value must be between 0 and 65535
seconds. By default, this value is 300 seconds. Tick the
Infinite
option, to disable
the write delay feature.
Click the
Apply
button to accept the changes made.
The fields that can be configured for
Console Log Settings
are described below:
Parameter
Description
Console Log State
Select whether the enable or disable the console log’s global state here.
Severity
Select the severity value of the type of information that will be logged. Options to
choose from are
0 (Emergencies)
,
1 (Alerts)
,
2 (Critical)
,
3 (Errors)
,
4
(Warnings)
,
5 (Notifications)
,
6 (Informational)
, and
7 (Debugging)
.
Discriminator Name
Enter the discriminator name used here. This name can be up to 15 characters
long.
Click the
Apply
button to accept the changes made.
The fields that can be configured for
SMTP Log Settings
are described below:
Parameter
Description
SMTP Log State
Select whether the enable or disable the SMTP log’s global state here.
Severity
Select the severity value of the type of information that will be logged. Options to
choose from are
0 (Emergencies)
,
1 (Alerts)
,
2 (Critical)
,
3 (Errors)
,
4
(Warnings)
,
5 (Notifications)
,
6 (Informational)
, and
7 (Debugging)
.
Discriminator Name
Enter the discriminator name used here. This name can be up to 15 characters
long.
Click the
Apply
button to accept the changes made.
System Log Discriminator Settings
This window is used to display and configure the system log’s discriminator settings.
To view the following window, click
System > System Log > System Log Discriminator Settings
, as shown below:
Содержание DXS-3400 SERIES